20
Step 3: Remove Clamps
From the bottom of the unit, locate the four hoses that go to the air breaker as indicated with the
arrows in the below image.
Use a flat tip screwdriver to pry the clips securing the ends of the clamp together.
Remove clamp and discard.
Remove the hoses from the air breaker.
Step 4: Disconnect Electrical Connections
Remove the electrical connector from the side of the Air Breaker where indicated in the image
below
IMPORTANT NOTE ON CRIMP CLAMPS
The factory installed crimp clamps are not reusable.
Gear drive hose clamps (not supplied) are required
to complete repair.
To remove, use a flat tip screwdriver to pry the
clamp apart as noted in the below sample image.
Summary of Contents for DWP62BL
Page 11: ...10 Wiring Diagram...