18
6. Remove the 2 snap fittings that attach the PCB to the control box.
7. Disconnect the wire connections and replace the PCB.
Water Inlet Valve
The water inlet valve is electronically controlled and solenoid-operated. The water valve
has an approx
imate resistance value of 1 KΩ. The water valve is mounted on a bracket
located on the left side of the front brace. To remove the water valve:
1. Disconnect the power.
2. Remove the 2 screws from the kick plate and the 2 screws from the insulating
panel.
3. Remove the 90° elbow for the water line.
4. Remove the side plate.