EdgeStar AP13000W Owner'S Manual Download Page 14

11 

 
To set the temperature in cooling mode, use the Minus and Plus 
buttons on the remote. The temperature range is 61° to 86° 
Fahrenheit.  Adjust the temperature until you reach your desired 

setting. 

 
In this mode, the air conditioner is set to run at the lowest 
temperature 61°F and high fan speed.  To activate this function 
mode, press the TURBO button on the remote control ONLY. 
 
This function mode enables a delayed switch ON or OFF for this air 
conditioner.  The time (hours) delay can be set, enable, and 
disabled from the both the remote control and control panel. 

 

SETTING DELAYED SWITCH ON TIMER FROM REMOTE 
CONTROL  

Switch on the air conditioner, select the function mode (cooling/ fan only / 
dehumidifying only), set temperature and fan speed. Then switch off the 
unit. To activate the delayed switch on function, press the ON timer 
button and set the desired time delay ON hours (from 1 to 12 hours) by 
pressing the ON timer button. Once the delayed switch on timer is set, 
press the SET timer button to confirm the setting. The symbol and the 
delay countdown timer will appear on the remote control display. When 
the delay time set has elapsed, the air conditioner switches on with last 
selected settings. To cancel the delayed switch on function, press timer 
button until symbol disappears on the display.  
 

SETTING SWITCH ON TIMER FROM CONTROL PANEL  

Switch on the air conditioner, select the function mode (cooling/ fan only / 
dehumidifying only), set temperature and fan speed. Then switch off the 
unit. Press the Timer button and set the desired time delay ON hours 
(from 1 to 12 hours) by pressing the 

and 

– 

buttons. Once the delayed 

switch on timer is set, press the Timer button to confirm the setting. The 
symbol and the delay countdown timer will appear on the control panel 
display. When the delay time set has elapsed, the air conditioner switches 
on with last selected settings. To cancel the delayed switch on function, 
press Timer button until symbol disappears on the display.  
 

SETTING SWITCH OFF TIMER FROM REMOTE CONTROL  

With the air conditioner operating in any function mode, press the OFF 
timer button  then set the desired time delay OFF hours (from 1 to 12 
hours) by pressing the OFF timer button. Once the delayed switch off 
timer is set, press the SET timer button to confirm the setting. The symbol 
and the delay countdown timer will appear on the remote control display. 
When the delay time set has elapsed, the air conditioner switches off. To 
cancel the delayed switch off function, press until symbol disappears on 
the display. 

 

 

 
SETTING SWITCH OFF TIMER FROM CONTROL PANEL  

Setting the Temperature 

Turbo Mode

 

Timer (Delayed Switch 
ON/OFF) Function

 

Summary of Contents for AP13000W

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP13000W...

Page 2: ...designed for indoor use only Do not use the unit in extremely humid or wet environments Do not spray water and wet the housing or control panel Do not pull the unit by the cord Always turn the unit of...

Page 3: ...REMOTE CONTROL OVERVIEW 8 INSTALLING THE BATTERIES 9 OPERATING THIS UNIT 9 LCD DISPLAY 9 POWER BUTTON 9 AUTO RESTART 9 FAN MODE ONLY 9 REPLACING THE BATTERIES COOLING MODE 9 DEHUMIDIFYING MODE 10 SLEE...

Page 4: ...the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your w...

Page 5: ...ntification Front View Back View Parts Key 1 Control Panel 2 Air Outlet Vent 3 Handle 4 Castors 5 Air Filter Grille Intake 6 Air Outlet Heat Exhaust 7 Air Inlet 8 Power Cord 9 Drain Plug 10 Air Filter...

Page 6: ...e outdoor exhaust hose outlet at the back of the air conditioner 2 Attach the round connector to the opposite end of the exhaust hose Exhaust Hose Rectangular Connector Adjustable Window Panel Window...

Page 7: ...stalled on a horizontal or vertical sliding window as shown in the pictures below Attach the window panel to the window panel If the inner width of the window is less than 21 530 mm wide 1 Remove the...

Page 8: ...e unit towards the window kit installed Leave a space at least 20 inches to the wall Connect your exhaust hose to the window kit installed After you have installed the exhaust hose and window kit you...

Page 9: ...then the hose by adding additional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recomm...

Page 10: ...gh Medium and Low Up and Down Press to increase or decrease the set temperature Timer The timer can be used to either turn the unit on or off after a number of elapsed hours The temperature range for...

Page 11: ...Sleep Mode on or off 4 Unit switch ON delay setting 5 Turns unit off and off 6 Changes temperature between Celsius and Fahrenheit NOTE Be careful not drop the remote control Do not place the remote co...

Page 12: ...panel until fan only symbol appears on the displays There are three fan speeds High Fan Speed Medium Fan Speed Low Fan Speed Cooling mode cools and dehumidifies the air If the ambient temperature dro...

Page 13: ...nute transition time During the Sleep Mode the air conditioner gradually increases the set temperature in cooling mode decreases the noise level and conserves energy In Sleep mode the temperature is m...

Page 14: ...tch on function press timer button until symbol disappears on the display SETTING SWITCH ON TIMER FROM CONTROL PANEL Switch on the air conditioner select the function mode cooling fan only dehumidifyi...

Page 15: ...nsure they do not obstruct the air intake Minimize the length of the exhaust hose Make sure the exhaust hose is as straight as possible and avoid kinks or bends Keep curtains blinds or drapes closed d...

Page 16: ...the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in...

Page 17: ...it is on a level surface A foreign object has jammed the fan Remove the object from the fan The floor below the unit is uneven Move the unit to a level surface My air conditioner is making a continuou...

Page 18: ...oo large Minimize the size of the area to be cooled i e adding a drop ceiling Use more than one unit to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too m...

Page 19: ...tion of product Portable Air Conditioner Model AP13000W Voltage Frequency AC 115V 60Hz Input Power 960W Current 8 6A BTU 13 000 Color White Coolant Quantity R 410A 11 6oz Timer 12 Hour Dimensions WxHx...

Page 20: ...nstruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s ma...

Page 21: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: