Troubleshooting 

 
Follow the troubleshooting guide below to resolve common issues. 

Issue 

Possible Cause 

Solution 

My air conditioner is 
not functioning at all 

Unit is not receiving 
power 

Make sure the unit is 
plugged in 

LCDI power cord is 
tripped 

Press the Reset button 
on the LCDI cord  

Insufficient power 

Move the unit to 
another outlet. Check 
your circuit breaker. 
(Refer to the rating 
label on the back of 
the unit to determine 
the Amperage draw) 

Water reservoir is full 

Drain the unit and 
restart 

Control panel is 
disconnected 

If no indicator lights 
turn on, contact 
customer service 

My remote control 
does not work and the 
indicator light on 
remote does not turn 
on 

Batteries not installed  

Install new batteries 

Bad batteries 

Replace the batteries 

Batteries installed 
incorrectly 

Reinstall the batteries 
correctly 

A defective remote 
control 

Contact customer 
service 

My air conditioner is 
making a loud noise 

The unit is not level. 

Make sure the unit is 
on a level surface 

A foreign object has 
jammed the fan. 

Remove the object 
from the fan 

The floor below the 
unit is uneven 

Move the unit to a 
level surface 

My air conditioner is 
making a continuous 
metallic knocking or 
pinging sound 

Unit may have been 
shipped on its side 

Shut off the unit. Let 
the unit sit on a level 
surface for at least 24 
hours and restart. 

Damaged compressor 

Contact customer 
service 

My air conditioner is 
leaking 

Drain plug is removed 

Attach the drain plug 

Cracked base pan 

Contact customer 
service 

My air conditioner runs 
for a little while and 
then it trips the power 
cord or the circuit 
breaker 

The air conditioner 
may be plugged into 
an outlet that can not 
supply the correct 
amount of current 

Contact an electrician 
if the unit works in a 
different room or circuit 

The control panel 
lights blink randomly 

Unit may have a faulty 
control panel 

Contact customer 
service 

 

Summary of Contents for AP12000HS-1

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP12000HS 1...

Page 2: ...y This unit is designed for indoor use only Do not use the unit in extremely humid or wet environments Do not wet the housing or control panel Do not pull the unit by the cord Always turn the unit off...

Page 3: ...ECTOR TO THE GRATED ADAPTER 8 NOTES ABOUT THE EXHAUST HOSE 9 CONTROL PANEL OVERVIEW 10 OPERATING THE CONTROL PANEL 11 POWER 11 AUTO RESTART 11 COOLING MODE 11 DEHUMIDIFYING MODE 11 HEAT MODE 11 FAN ON...

Page 4: ...the ratings label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for...

Page 5: ...ts Identification Back View Front View Control Panel Front Air Vent Handle Caster Pre filter Air Intake Exhaust Outlet Power Cord Drain Valve CAUTION Make sure the rubber drain plug is firmly installe...

Page 6: ...eded It is necessary to clean the pre filter periodically Follow the steps below to install the carbon filter 1 Pull the handle on the pre filter straight up CAUTION Never operate the air conditioner...

Page 7: ...e power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window as show...

Page 8: ...ter 1 Insert the round grated adapter through the back grooved side of the window kit plate with hole 2 Secure the grated adapter by fastening the screws from flat side of the window kit plate to the...

Page 9: ...ndow sill Then slide the window kit plate to fit the width of the window You can use screws to secure the window kit plate from sliding 4 Lower the window to secure the window kit in place You may nee...

Page 10: ...hose A B 5 Attach the connectors to the hose A Extend the ends of the exhaust hose B Thread the duct connector on by turning it clockwise until it stops 6 Roll the unit towards the window kit Leave a...

Page 11: ...ortable air conditioner and start using it Connecting the duct connector to the unit Connecting the duct connector to the grated adapter 7 Align the slots on the duct connector to the tabs and snap in...

Page 12: ...ditional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommended Draining the Unit Wh...

Page 13: ...mer button is enabled Indicator Function Water Light The water light will turn on if the unit has filled the internal water reservoir Timer Light The timer light indicates you have set the timer Use t...

Page 14: ...adjustable between 61 F 89 F in one degree increments in cooling mode During the Dehumidifying mode the unit will condense water out of the air and exhaust it through the exhaust hose The ambient temp...

Page 15: ...r the selected time passes the unit will automatically turn on How to set the unit to automatically turn off 1 Press the Timer button while the unit is powered on The Timer indicator LED will light up...

Page 16: ...e control will not be used for one month or longer Do not attempt to recharge batteries not designed to be recharged All batteries should be replaced at the same time Do not mix old and new batteries...

Page 17: ...urn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources direct sunligh...

Page 18: ...nse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in a cool and shaded place Dry thoroughly before reinstalli...

Page 19: ...orrectly A defective remote control Contact customer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fa...

Page 20: ...t to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The...

Page 21: ...tion of product Portable Air Conditioner Model AP12000HS 1 Voltage Frequency AC 115V 60Hz Input Power 1200W Cooling 1180W Heating Color Silver Dehumidifying capacity 81 Pints Day Coolant R 410A Timer...

Page 22: ...er installation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacem...

Page 23: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: