Edge-Core ES4524D Installation Manual Download Page 28

2-4

Network Planning

2

Remote Connections with Fiber Cable

Fiber optic technology allows for longer cabling than any other media type. A 
1000BASE-SX (MMF) link can connect to a site up to 550 meters away, a 
1000BASE-LX (SMF) link up to 5 km, and a 1000BASE-LH link up to 70 km. This 
allows a switch to serve as a collapsed backbone, providing direct connectivity for a 
widespread LAN. 

A 1000BASE-SX SFP transceiver can be used for a high-speed connection between 
floors in the same building and a 1000BASE-LX SFP transceiver can be used for 
core connections between buildings in a campus setting. And for long-haul 
connections, a 1000BASE-LH SFP transceiver can be used to reach another site up 
to 70 kilometers away.

The figure below illustrates the switch connecting multiple segments with fiber cable.

Figure 2-3  Remote Connections with Fiber Cable

...

...

Headquarters

1000BASE-LX SMF
(5 kilometers)

Remote Switch

1000BASE-SX MMF
(500 meters)

Remote Switch

Server Farm

...

Warehouse

Research & Development

1000BASE-LX SMF
(5 kilometers)

10/100/1000 Mbps Segments

...

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Power

RPS

Diag

21

22

23

24

ES4524D

Console

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Power

RPS

Diag

21

22

23

24

ES4524D

Console

Summary of Contents for ES4524D

Page 1: ...www edge core com Installation Guide Powered by Accton Installationsanleitung Installationsanleitung ES4524D ES4548D 24 48 Port Gigabit Ethernet Switch...

Page 2: ......

Page 3: ...thernet Switch Layer 2 Switch with 20 10 100 1000BASE T RJ 45 Ports and 4 Gigabit Combination Ports RJ 45 SFP ES4548D Gigabit Ethernet Switch Layer 2 Switch with 44 10 100 1000BASE T RJ 45 Ports and 4...

Page 4: ...ES4524D ES4548D E112006 CS R01 150200055800A...

Page 5: ...t expressly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 1...

Page 6: ...of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000...

Page 7: ...er SELV Safety Extra Low Voltage conditions according to IEC 60950 The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions France and Peru only...

Page 8: ...lectrique au niveau de cette prise L appareil fonctionne une tension extr mement basse de s curit qui est conforme la norme IEC 60950 Ces conditions ne sont maintenues que si l quipement auquel il est...

Page 9: ...ts kann nur durch Herausziehen des Ger tenetzkabels aus der Netzsteckdose unterbrochen werden Der Betrieb dieses Ger ts erfolgt unter den SELV Bedingungen Sicherheitskleinstspannung gem IEC 60950 Dies...

Page 10: ...rectly at a transmit port when it is powered on Caution Wear an anti static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment Caution Do not p...

Page 11: ...no hazardous nor ozone depleting materials in this product Documentation All printed documentation for this product uses biodegradable paper that originates from sustained and managed forests The inks...

Page 12: ...viii...

Page 13: ...rk Planning 2 1 Introduction to Switching 2 1 Application Examples 2 2 Collapsed Backbone 2 2 Network Aggregation Plan 2 3 Remote Connections with Fiber Cable 2 4 Making VLAN Connections 2 5 Applicati...

Page 14: ...shooting A 1 Diagnosing Switch Indicators A 1 Diagnosing Power Problems with the LEDs A 1 Power and Cooling Problems A 1 Installation A 2 In Band Access A 2 Appendix B Cables B 1 Twisted Pair Cable an...

Page 15: ...xi Contents Montage Rack Mounting Instructions German B 2 Rack Montage B 2 Glossary Index...

Page 16: ...rnet Cable Length 4 5 Table 4 3 Maximum 1000BASE LX Gigabit Ethernet Cable Length 4 5 Table 4 4 Maximum 1000BASE LH Gigabit Ethernet Cable Length 4 5 Table 4 5 Maximum Fast Ethernet Cable Length 4 5 T...

Page 17: ...J 45 Connections 3 2 Figure 3 2 Attaching the Brackets 3 3 Figure 3 3 Installing the Switch in a Rack 3 4 Figure 3 4 Attaching the Adhesive Feet 3 4 Figure 3 5 Inserting an SFP Transceiver into a Slot...

Page 18: ...xiv Figures...

Page 19: ...Switching and Virtual LANs It brings order to poorly performing networks by segregating them into separate broadcast domains with IEEE 802 1Q compliant VLANs empowers multimedia applications with mult...

Page 20: ...r validity before being forwarded This prevents errors from being propagated throughout the network Network Management Options These switches contain a comprehensive array of LEDs for at a glance moni...

Page 21: ...sceiver slots are shared with four of the RJ 45 ports ports 21 24 for the ES4524D and ports 45 48 for the ES4548D In its default configuration if an SFP transceiver purchased separately is installed i...

Page 22: ...Figure 1 5 Power Supply Sockets Table 1 2 System Status LEDs LED Condition Status Power Green Internal power is operating normally Amber Internal power supply failure Off Power off or failure RPS Gre...

Page 23: ...for 100 Mbps connections and Category Category 5 5e 6 or better for 1000 Mbps connections IEEE 802 3 2005 Ethernet Fast Ethernet and Gigabit Ethernet compliance ensures compatibility with standards ba...

Page 24: ...Introduction 1 6 1...

Page 25: ...device experiencing congestion server power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize thro...

Page 26: ...kstations or servers You can easily build on this basic configuration adding direct full duplex connections to workstations or servers When the time comes for further expansion just connect to another...

Page 27: ...plex network down into a single efficient bridged node increasing overall bandwidth and throughput In the figure below the 10 100 1000BASE T ports are providing 1000 Mbps connectivity through Layer 2...

Page 28: ...used for core connections between buildings in a campus setting And for long haul connections a 1000BASE LH SFP transceiver can be used to reach another site up to 70 kilometers away The figure below...

Page 29: ...a single switch However tagged VLANs should be used for larger networks and all the VLANs assigned to the inter switch links These switches also support multiple spanning trees which allow VLAN groups...

Page 30: ...hat require routing between dissimilar network types you can attach these switches directly to a multi protocol router 3 As a general rule the length of fiber optic cable for a single switched link sh...

Page 31: ...sure that the unit is connected to a separate grounded power outlet that provides 100 to 240 VAC 50 to 60 Hz is within 2 m 6 6 feet of each device and is powered from an independent circuit breaker As...

Page 32: ...our adhesive foot pads Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power cord either US Continental Europe or UK Console cable RJ 45 to RS 23...

Page 33: ...t the rack environment temperature is within the specified operating temperature range See page C 1 Mechanical Loading Do not place any equipment on top of a rack mounted unit Circuit Overloading Be s...

Page 34: ...apter 4 If installing multiple switches mount them in the rack one below the other in any order 5 If also installing an RPS mount it in the rack below the other devices Desktop or Shelf Mounting 1 Att...

Page 35: ...SFP compatible transceivers To install an SFP transceiver do the following 1 Consider network and cabling requirements to select an appropriate SFP transceiver type 2 Insert the transceiver with the...

Page 36: ...the device is powered on to be sure the Power LED is on If not check that the power cable is correctly plugged in 4 If you have purchased a Redundant Power Supply connect it to the switch and to an AC...

Page 37: ...Baud rate 9 600 bps Character Size 8 Characters Parity None Stop bit One Data bits 8 Flow control none Table 3 1 Serial Cable Wiring Switch s 8 Pin Serial Port Null Modem PC s 9 Pin DTE Port 6 RXD rec...

Page 38: ...3 8 Installing the Switch 3...

Page 39: ...both ends Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections Cabling Guidelines The RJ 45 ports...

Page 40: ...n is made the Link LED on the switch corresponding to each port will light green 1000 Mbps or amber 10 100 Mbps to indicate that the connection is valid Network Wiring Connections Today the punch down...

Page 41: ...ents of a Class 1 Laser Product and are inherently eye safe in normal operation However you should never look directly at a transmit port when it is powered on Note When selecting a fiber SFP device c...

Page 42: ...an be attached in only one orientation Figure 4 3 Making Connections to SFP Transceivers 4 As a connection is made check the Link LED on the switch corresponding to the port to be sure that the connec...

Page 43: ...00BASE T Gigabit Ethernet Cable Length Cable Type Maximum Cable Length Connector Category 5 5e 6 100 ohm UTP or STP 100 m 328 ft RJ 45 Table 4 2 Maximum 1000BASE SX Gigabit Ethernet Cable Length Fiber...

Page 44: ...plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it is connected Note the length of each cable and the maximum cable lengt...

Page 45: ...your dealer for assistance Power LED is Amber Internal power supply has failed Contact your local dealer for assistance Diag LED is Amber Power cycle the switch to try and clear the condition If the c...

Page 46: ...ools However you must first configure the switch with a valid IP address subnet mask and default gateway If you have trouble establishing a link to the management agent check to see if you have a vali...

Page 47: ...re numbered Be sure to hold the connectors in the same orientation when attaching the wires to the pins Figure B 1 RJ 45 Connector Pin Numbers 10BASE T 100BASE TX Pin Assignments Use unshielded twiste...

Page 48: ...s labeled with an X MDI a crossover must be implemented in the wiring When auto negotiation is enabled for any RJ 45 port on these switches you can use either straight through or crossover cable to co...

Page 49: ...of any twisted pair connection does not exceed 100 meters 328 feet Table B 2 1000BASE T MDI and MDI X Port Pinouts Pin MDI Signal Name MDI X Signal Name 1 Bi directional Data One Plus BI_D1 Bi directi...

Page 50: ...ion does not meet one of the test parameters for 1000BASE T there are basically three measures that can be applied to try and correct the problem 1 Replace any Category 5 patch cables with high perfor...

Page 51: ...45 100 ohm UTP cable Category 5 or better 1000BASE T RJ 45 100 ohm UTP or STP cable Category 5 5e or 6 Maximum Cable Length 100 m 328 ft Buffer Architecture ES4524D 0 75 Mbytes ES4548D 1 5 Mbytes two...

Page 52: ...t power supply Power Consumption ES4524D 54 Watts ES4548D 89 Watts Maximum Current ES4524D 0 59 A 110 VAC 0 36 A 240 VAC ES4548D 0 97 A 110 VAC 0 47 A 240 VAC Switch Features Forwarding Mode Store and...

Page 53: ...IEEE 802 1w Rapid Spanning Tree Protocol IEEE 802 1s Multiple Spanning Tree Protocol IEEE 802 1Q Virtual LAN ISO IEC 8802 3 CSMA CD Compliances CE Mark Emissions FCC Class A Industry Canada Class A EN...

Page 54: ...C 4 Specifications C...

Page 55: ...eichende Beluftung aufgestellt werden F r das Installieren die Kabelverlegung und f r Wartungen und Reparaturen leicht zug nglich sein Die LED Statusanzeigedioden mussen stets klar und leicht sichtbar...

Page 56: ...1 Mechanische Last Stellen Sie kein Ger t auf eine Rack Montageeinheit Strom berlastung Stellen Sie sicher dass der Netzkreis der Rackeinheit nicht berlastet wird Erdung Die Rack Montageeinheit muss r...

Page 57: ...25 or 62 5 125 micron core fiber cable 1000BASE T IEEE 802 3ab specification for Gigabit Ethernet over 100 ohm Category 5 5e or 6 twisted pair cable using all four wire pairs Auto Negotiation Signalli...

Page 58: ...Fast Ethernet A 100 Mbps network communication system based on Ethernet and the CSMA CD access method Full Duplex Transmission method that allows two network devices to transmit and receive concurrent...

Page 59: ...rmation Base It is a set of database objects that contains information about the device Modal Bandwidth Bandwidth for multimode fiber is referred to as modal bandwidth because it varies with the modal...

Page 60: ...er protocol UTP Unshielded twisted pair cable Virtual LAN VLAN A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection p...

Page 61: ...3 safety C 3 connectivity rules 10 Mbps 4 6 100 Mbps 4 5 1000 Mbps 4 5 console port pin assignments 3 6 contents of package 3 2 cooling problems A 1 cord sets international 3 6 D DC input 1 4 desktop...

Page 62: ...lems troubleshooting A 1 R rear panel receptacles 1 4 redundant power unit 1 4 RJ 45 port 1 3 connections 4 1 pinouts B 3 RPU connecting 3 6 installing in a rack 3 4 installing on a desktop 3 5 option...

Page 63: ......

Page 64: ...ES4524D ES4548D E112006 CS R01 150200055800A...

Reviews: