8
Cables
Cable Specifications
Caution: DO NOT
plug a phone jack connector into
any RJ-45 port. Use only twisted-pair cables
with RJ-45 connectors that conform with
FCC standards.
Use 100-ohm unshielded twisted-pair (UTP) or
shielded twisted-pair (STP) cable for RJ-45
connections: Category 3, 4, or 5 cable for 10 Mbps connections,
Category 5, 5e cable for 100 Mbps connections, or Category 5, 5e or 6 for
1000 Mbps connections. Also be sure that the length of any twisted-pair connection
does not exceed 100 meters (328 feet).
10BASE-T/100BASE-TX Pin Assignments
Because all ports on this switch support automatic MDI/MDI-X operation, you can
use straight-through cables for all network connections to PCs or servers, or to other
switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the
cable, are connected straight through to pins 1, 2, 3 and 6 at the other end of the
cable.
The table below shows pinout signals for connections to 10BASE-T/100BASE-TX
devices.
Cable Types and Specifications
Cable
Type
Max. Length
Connector
10BASE-T
Cat. 3, 4, 5 100-ohm UTP
100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
100 m (328 ft)
RJ-45
1000BASE-T
Cat. 5, 5e, 6 100-ohm UTP
100 m (328 ft)
RJ-45
Pin
MDI-X Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
4,5,7,8
Not used at 10/100 Mbps
Not used at 10/100 Mbps
1
8
8