background image

–  1  –

Q u i c k   St a r t   G u i d e

10/28-Port Web-Smart Pro Gigabit Ethernet Switch

ECS2100-10T/ECS2100-10P/ECS2100-10PE
ECS2100-28T/ECS2100-28P/ECS2100-28PP

The ECS2100 series switches include the following models:  

ECS2100-10T— 8 10/100/1000BASE-T + 2 SFP uplink ports
ECS2100-10PE— 8 10/100/000BASE-T + 2 SFP uplink ports (4 PoE ports) 
ECS2100-10P— 8 10/100/1000BASE-T + 2 SFP uplink ports (8 PoE ports) 
ECS2100-28T— 24 10/100/000BASE-T + 4 SFP uplink ports 
ECS2100-28P— 24 10/100/000BASE-T + 4 SFP uplink ports (24 PoE ports) 
ECS2100-28PP— 24 10/100/000BASE-T + 4 SFP uplink ports (24 PoE ports) 

N

OTE

:

 

The ECS2100 series switches are for indoor use only.

N

OTE

:

 

For Safety and Regulatory information, refer to the 

Safety and Regulatory 

Information

 document included with the switch.

ECS2100-10PE

ECS2100-10P

ECS2100-10T

ECS2100-28P

ECS2100-28PP

ECS2100-28T

E012016-AP-R01

150200001318A

www.edge-core.com

Summary of Contents for ECS2100 Series

Page 1: ...0 100 1000BASE T 2 SFP uplink ports 8 PoE ports ECS2100 28T 24 10 100 000BASE T 4 SFP uplink ports ECS2100 28P 24 10 100 000BASE T 4 SFP uplink ports 24 PoE ports ECS2100 28PP 24 10 100 000BASE T 4 SF...

Page 2: ...nd CLI Reference Guide can be obtained from www edge core com support download user manual 2 Install the Switch Rack Mounting The switch can be mounted in a standard 19 inch rack or on a desktop or sh...

Page 3: ...ource to power on Verify that the external AC power requirements for the switch can be met as listed below ECS2100 10T AC 100 240 V 50 60 Hz 0 5 A ECS2100 10P AC 100 240 V 50 60 Hz 2 1 A ECS2100 28T A...

Page 4: ...ding terminal screw on the switch rear panel must be permanently connected to earth 5 Verify Switch Operation Verify basic switch operation by checking the system LEDs When operating normally the Diag...

Page 5: ...as a default management IP address of 192 168 2 10 and a subnet mask of 255 255 255 0 You must set your PC IP address to be on the same subnet as the switch that is the PC and switch addresses must bo...

Page 6: ...ansceivers are supported 1000BASE SX ET4201 SX 1000BASE LX ET4201 LX 1000BASE ZX ET4201 ZX As connections are made check the port status LEDs to be sure the links are valid 8 Optional Extend PoE Budge...

Page 7: ...9 inch rack and power on Install the PS3000 chassis in a standard 19 inch rack Install one or more EPS460W PSUs in the chassis The chassis can support up to three EPS460W PSUs Use the PSU cable provid...

Page 8: ...s are measured under a 100 percent loading test and should be used as estimates for planning purposes AC Input Power ECS2100 10T AC 100 240 V 50 60 Hz 0 5 A ECS2100 10P AC 100 240 V 50 60 Hz 2 1 A ECS...