Quick Start Guide
– 2 –
2. Install the Switch
The switch can be mounted in a standard 19-inch rack or on a desktop or shelf.
Following your rack plan, mark the holes in the rack where the switch will be
installed. Lift the switch into the rack and hold it in a position aligned with the
marked holes. Secure the switch in the rack, using four rack-mounting screws (not
provided).
3. Ground the Switch
Before powering on the switch, ground the switch to earth.
Ensure the rack on which the switch is to be mounted is properly grounded and in
compliance with ETSI ETS 300 253. Verify that there is a good electrical connection
to the grounding point on the rack (no paint or isolating surface treatment.).
Caution:
The earth connection must not be removed unless all supply
connections have been disconnected