Chapter 8
| General Security Measures
Web Authentication
– 275 –
name and password authentication via RADIUS. Once authentication is successful,
the web browser is forwarded on to the originally requested web page. Successful
authentication is valid for all hosts connected to the port.
Note:
RADIUS authentication must be activated and configured for the web
authentication feature to work properly (see
Note:
Web authentication cannot be configured on trunk ports.
web-auth
login-attempts
This command defines the limit for failed web authentication login attempts. After
the limit is reached, the switch refuses further login attempts until the quiet time
expires. Use the
no
form to restore the default.
Syntax
web-auth login-attempts
count
no web-auth login-attempts
count
- The limit of allowed failed login attempts. (Range: 1-3)
Default Setting
3 login attempts
Table 53: Web Authentication
Command
Function
Mode
Defines the limit for failed web authentication login
attempts
GC
Defines the amount of time to wait after the limit for
failed login attempts is exceeded.
GC
Defines the amount of time a session remains valid
GC
Enables web authentication globally for the switch
GC
Enables web authentication for an interface
IC
web-auth re-authenticate (Port)
Ends all web authentication sessions on the port and
forces the users to re-authenticate
PE
Ends the web authentication session associated with the
designated IP address and forces the user to re-
authenticate
PE
Displays global web authentication parameters
PE
Displays interface-specific web authentication
parameters and statistics
PE
Displays a summary of web authentication port
parameters and statistics
PE
Summary of Contents for AS5700-54X
Page 42: ...Contents 42...
Page 44: ...Figures 44...
Page 52: ...Tables 52...
Page 54: ...Section I Getting Started 54...
Page 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 358: ...Chapter 9 Access Control Lists ACL Information 358...
Page 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Page 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Page 442: ...Chapter 16 Address Table Commands 442...
Page 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Page 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Page 544: ...Chapter 20 Quality of Service Commands 544...
Page 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Page 680: ...Chapter 23 LLDP Commands 680...
Page 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Page 732: ...Chapter 25 Domain Name Service Commands 732...
Page 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Page 1072: ...Section III Appendices 1072...
Page 1102: ...List of CLI Commands 1102...
Page 1115: ......
Page 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...