Edge-Core AGR420 Quick Start Manual Download Page 2

–  2  –

Mount the Device

1.

Separate the rack-rail assembly into two sections.

2.

Use the included ten screws to attach the bracket to each side of the 
device.

3.

Slide the device into the rack.

4.

Hold it in place and secure the rack-assembly to the front post using 
four screws.

5.

While holding the device in place, slide the inner section of rack-rail 
assembly from the back until it fits the rear post. 

6.

Secure the rack-rail assembly to the rear using four screws.

Ground the Device

Connect Power

DC Power 

Install two DC PSUs and then connect them to a DC power source.

Warning:

 

For a safe and reliable installation, use only 

the accessories and screws provided with the device. Use 

of other accessories and screws could result in damage to 

the unit. Any damages incurred by using unapproved 

accessories are not covered by the warranty.

Avertissement:

 Pour une installation sûre et fiable, 

utilisez uniquement les accessoires et les vis fournies avec 

l’appareil. L’utilisation d’autres accessoires et vis pourrait 

endommager l’appareil. Les dommages causés par 

l’utilisation d’accessoires non approuvés ne sont pas 

couverts par la garantie.

Caution:

 The device must be installed in a restricted-access 

location.

Attention: 

L’appareil doit être installé dans un emplacement 

à accès restreint.

Note:

 The drawings in this document are for illustration only 

and may not match your particular model.

1

Caution:

 The chassis ground connection must not be 

removed unless all supply connections have been 

disconnected.

Attention:

 Le raccordement à la terre ne doit pas être retiré 

sauf si toutes les connexions d’alimentation ont été 

débranchées.

Caution:

 The device must be installed in a restricted-access 

location. It should have a separate protective ground terminal 

on the chassis that must be permanently connected to a well 

grounded chassis or frame to adequately ground the device 

chassis and protect the operator from electrical hazards.

Attention:

 

L'appareil doit être installé dans un emplacement 

à accès restreint. Il doit comporter une borne de terre de 

protection distincte sur le châssis, qui doit être connectée en 

permanence à la terre pour assurer une mise à la terre 

adéquate du châssis et protéger l'opérateur des risques 

électriques.

2

Verify Rack Ground

Ensure the rack on which the device is to be mounted is properly 
grounded and in compliance with ETSI ETS 300 253. Verify that there is 
a good electrical connection to the grounding point on the rack (no 
paint or isolating surface treatment).

Attach Grounding Wire

Attach a lug (not provided) to a #8 AWG minimum grounding wire (not 
provided), and connect it to the grounding point on the device rear 
panel. Then connect the other end of the wire to rack ground.

3

Installation

Quick Start Guide

Summary of Contents for AGR420

Page 1: ...ng kit 2 rack rail assemblies and 20 screws 3 Console cable RJ 45 to D Sub 4 Documentation Quick Start Guide this document and Safety and Regulatory Information Package Contents Overview 1 2 4 3 Front...

Page 2: ...acc s restreint Note The drawings in this document are for illustration only and may not match your particular model 1 Caution The chassis ground connection must not be removed unless all supply conne...

Page 3: ...ivent tre effectu es par un professionnel qualifi Note Use 8 AWG 6 mm2 copper wire for a 40 to 75 VDC PSU to connect to a DC PSU 2 3 1 4 4 5 100G QSFP DD Ports Install transceivers and then connect fi...

Page 4: ...non condensing Storage 5 to 95 non condensing Power Consumption 527 W at 25 C 77 F 723 W at 45 C 113 F 48 VDC PSU DC Input 40 75 VDC 40 A max AC PSU AC Input 100 120 VAC 50 60 Hz 12 A Max 200 240 VAC...

Page 5: ...z 5 USB 6 RJ 45 7 8 9 1 x Micro USB 1 x RJ 45 10 11 12 13 5 x 12 13 www edge core com 1 AS7946 74XKSB 2 2 20 3 RJ 45 D Sub 4 1 2 4 3 LED FRU 1 QSFP DD LED LED1 100G LED2 2 QSFP28 LED LED1 100G 40G LED...

Page 6: ...6 1 2 3 4 5 6 2 PSU 1 2 ETSI ETS 300 253 8 AWG 3...

Page 7: ...1PPS OUT IEC UL EN 60950 1 62368 1 8 AWG 6 mm2 40 75 VDC PSU PSU 2 3 1 4 4 5 100G QSFP DD QSFP DD 8 16 5W 100G QSFP28 QSFP28 100GBASE SR4 LR4 CWDM4 DR1 40GBASE SR4 LR4 DAC QSFP28 SFP28 SFP28 25GBASE...

Page 8: ...200 240 V 50 60 Hz 7 5 A Max EN 55032 2015 A1 2020 EN 61000 3 2 2019 A1 2021 EN 61000 3 3 2013 A1 2019 FCC Part 15 subpart B Class A CCC GB T 9254 1 2021 Class A BSMI VCCI EN 55024 2010 A1 2015 EN 55...

Reviews: