OTHER CONSIDERATIONS

 

 
Suggested Speaker Systems 

– Your 

speaker system, should be chosen to 
accommodate the characteristics of your 
amplifier and your predominant application.  
If you will only be using one cabinet. It will 
be at 8 Ohms as are all the CXC models.  
 
If you are using two cabinets, they should 
both be 8 Ohm models so their combined 
impedance will be 4 ohms.  
 

Headphone Jack as Line Driver

 – On 

some occasions (such as high-volume or 
outdoor situations) it may be desirable to 
use the CXC-300/400 along with an 
additional power amplifier and added 
cabinets.  A standard shielded instrument 
cable may be used to connect from the 
headphone jack of the CXC-300/400 to an 
unbalanced input of a standard power 
amplifier.  This will provided a signal that is 
post EQ and master volume controls, 
allowing the entire system to be controlled 
from the CXC Amplifier.   
 

Using the CXC-300/400 With out 
Speakers 

  

This amplifier is designed to be used safely 
with headphones only, without the loud 
speaker plugged in. No harm will result from 
using the amplifier in this fashion.  This 
allows the use of the unit for practice with 
headphones and as a preamplifier with other 
amplifiers. 
 

MAINTENANCE 

 
Your Eden amplifier has been designed to 
require minimal routine maintenance.  
Attention to the following areas will ensure 
optimum performance of your amplifier. 
 

Contact Point Cleaning – 

One of the 

weakest links in most bass amplification 
systems are the solderless connection 
points where instruments, speaker cabinets, 
effects, and other devices are connected to 
the amplifier.  (The most vulnerable of these 
types of connection is the jack on your 
instrument).  In addition to contamination 
from airborne pollutants, these points are 

frequently assaulted by connectors that 
have picked up debris from dirty stages, 
cases, etc.  These points should be cleaned 
regularly with a cotton swab soaked in 
denatured alcohol or a commercially 
available de-oxidant.  Frequent cleaning of 
the plugs on your cords is also 
recommended. 
 

Dust Removal – 

You should periodically 

inspect the ventilation openings on the  and 
sides of the unit to ensure that they have not 
become blocked by accumulated dust.  
Vacuum the openings to remove any dust 
buildup. 
 

Tube Replacement

 –This system does 

not use tubes. The CXC amplifiers 
feature a discrete  FET front end 
coupled to Bi-FET OP Amplifiers for the 
preamplifier section.  

 

Service – 

In the event of amplifier 

malfunction, or questions about your unit’s 
operating features, you should contact the 
your Dealer, the factory, or one of our 
authorized service centers for assistance. 
 
 

Eden Electronics 

P.O. Box 338 

115 second Street 

Montrose, Minnesota   

55363 

 

(763) 675-1890 

 

(763) 675-3777(fax) 

 

eden@eden-electronics.com

 

 

http://www.eden-

electronics.com 

Summary of Contents for Solo CXC-300

Page 1: ...1 SOLO SERIES CXC 300 400 Discrete FET Bass Amplifier Owner s Manual 1 10 99 ...

Page 2: ...Please take the time to review this manual and to send in your warranty registration card CAUTION Your ears are your most important piece of equipment Unfortunately they cannot be replaced as easily as your other gear Please take the following warning seriously This product when used in combination with a sound source and loudspeakers or headphones may be capable of producing sound levels that cou...

Page 3: ...requency selection control these controls will boost or cut the selected frequency by 15 db They are flat at their 12 00 setting Treble This is a traditional shelving type tone control It provides 15 db of boost or cut The knee of the filter is at approximately 2KHz The control is flat at the 12 00 position EQ Clip Indicator Flashes to indicate clipping within the tone control circuit of the pream...

Page 4: ...rating temperature Usually it takes from 2 to 5 minutes before the unit will begin to operate again Note the D I will continue to operate normally even when the amplifier is in thermal shut down only the stage sound will be lost OPERATING INSTRUCTIONS MECHANICAL AND THERMAL ISSUES Your amplifier should always be placed for operation away from sources of moisture or heat Care should be taken not to...

Page 5: ...at you will need to boost or cut are dependent upon your instrument playing style speaker cabinets and venue Extreme settings of boost or cut are unlikely to be necessary or helpful We are frequently asked to provide suggested settings for various styles of play We have discovered though that most of our endorsers tend to set their EQ generally flat using varying amounts of the Enhance Control We ...

Page 6: ...ention to the following areas will ensure optimum performance of your amplifier Contact Point Cleaning One of the weakest links in most bass amplification systems are the solderless connection points where instruments speaker cabinets effects and other devices are connected to the amplifier The most vulnerable of these types of connection is the jack on your instrument In addition to contamination...

Page 7: ...7 EQ Settings Setting name _____________________ Setting name ___________________ Setting name _____________________ ...

Reviews: