4)  Add an “Alarm” user with a badge and fingerprint 

Note:

 An “Alarm” user can, by presenting his/her second fingerprint, activate or 

inactivate a third party alarm system. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You have 10 
seconds to present 
the first finger of 
the user to be 
added 

3 times

 

You have 10 seconds 
to present the second 
finger of the user to 
be added 

3 times

 

(if you do not enrol 
a second fingerprint, 
the badge added will 
be encrypted as for 
a standard user – 
without an alarm 
function) 

Present the Add 
Alarm badge at the 
same time as the 
badge for the user 
you want to add 

Present the badge for the user 
that you want to add again 
and wait for the enrolment 
confirmation BEEP 

Summary of Contents for INSIDE SOLO

Page 1: ...Lecteur Biom trique avec commande d ouverture d port e Biometric reader with remote opening control Notice technique Technical information...

Page 2: ...e 16 7 Suppression d un utilisateur en empreinte seule 17 8 Suppression de tous les utilisateurs empreintes seules et badges 17 Retour en configuration usine 18 Signal tique 19 Acknowledgement 20 Info...

Page 3: ...ran aise INSIDE Toute l quipe INSIDE vous remercie de votre int r t ainsi que de votre confiance pour notre solution de s curit Nous esp rons qu elle vous donnera enti re satisfaction dans la s curisa...

Page 4: ...doit tre install par une entreprise qualifi e Une installation et une utilisation incorrectes peuvent entra ner des risques de chocs lectri ques ou d incendie Avant d effectuer l installation lire la...

Page 5: ...s 175g Dimensions du bo tier 119 x 77 x 40mm Temp rature de fonctionnement 20 C 50 C 2 Commande d ouverture d port e Consommation maximale 200mA 12V Tension d alimentation 9 14VDC Poids 200g Dimension...

Page 6: ...4 fils 3 paires conseill es 1 200 m 0 6 mm SYT conseill Caract ristique Liaison sensible cran Recommand Pour atteindre 1 200 m vous devez installer de chaque extr mit du r seau une r sistance de 220...

Page 7: ...ote Pour raccorder une centrale d intrusion tierce veillez raccorder une masse commune entre le module de commande et la centrale Si entr e 0V Alarme en service ouverture impossible mise hors service...

Page 8: ...module de commande dispose de 3 switchs de configuration o Switchs 1 et 2 configuration de la temporisation de commande d ouverture o Switchs 3 configuration de la sortie Mise en hors service Alarme...

Page 9: ...du syst me due des courants de retour il est imp ratif d utiliser et de raccorder les diodes anti retour livr es avec le produit suivant le sch ma de c blage ci dessus M me lors de l utilisation d un...

Page 10: ...n du syst me due des courants de retour il est imp ratif d utiliser et de raccorder les diodes anti retour livr es avec le produit suivant le sch ma de c blage ci dessus M me lors de l utilisation d u...

Page 11: ...ous devez apprendre les 3 cartes de configuration Ajouter Ajouter Alarme et Supprimer au lecteur afin de le mettre en service Pour cela veuillez suivre la proc dure suivante Apr s cette tape votre pro...

Page 12: ...ge avec empreinte sur plusieurs lecteurs d un m me site afin d apprendre le m me code site tous les lecteurs donc ne pas refaire l ajout des badges sur chaque lecteur vous ne devez utiliser qu un seul...

Page 13: ...en vigueur dans le pays d installation 1 Ajouter un utilisateur en badge plus empreinte Pr sentez le badge Ajouter en m me temps que le badge de l utilisateur que vous souhaitez ajouter Vous avez 10...

Page 14: ...et attendez le BIP de confirmation d enr lement Pr sentez le badge Ajouter en m me temps que le badge de l utilisateur que vous souhaitez ajouter Vous avez 10 secondes pour pr senter le premier doigt...

Page 15: ...oigt de l utilisateur ajouter 3 fois Vous avez 10 secondes pour pr senter le second doigt de l utilisateur ajouter 3 fois si vous n enr lez pas de seconde empreinte le badge ajout sera encod en tant q...

Page 16: ...ur ajouter 3 fois Vous avez 10 secondes pour pr senter le second doigt de l utilisateur ajouter 3 fois si vous n enr lez pas de seconde empreinte l utilisateur ajout n aura pas de fonction alarme Pr s...

Page 17: ...rs empreintes seules et badges Pr sentez le badge Supprimer Vous avez 10 secondes pour pr senter un des 2 doigts de l utilisateur supprimer Si l utilisateur est reconnu il sera aussit t supprim Pr sen...

Page 18: ...te des badges de configuration vous devrez repasser le lecteur en configuration usine pour lui apprendre un nouveau jeu de badges de configuration Cette manipulation supprimera tous les utilisateurs e...

Page 19: ...ernativement Lecteur en configuration usine attente des badges de configuration Ajouter Ajouter Alarme Suppri mer Clignote teinte Fonctionnement normal attente d un utilisateur Allum e Porte ouverte A...

Page 20: ...mpany INSIDE The entire INSIDE team would like to thank you for your interest as well as your confidence in our security solution We hope that you will be completely satisfied with the level of securi...

Page 21: ...standard NF EN 61000 4 4 o This product must be installed by an approved company Incorrect installation and usage may result in electric shock or fire Before installing the product read the technical...

Page 22: ...9 14VDC Weight 175 g Housing dimensions 119 x 77 x 40 mm Operating temperature 20 C to 50 C 2 Remote control opening Maximum power consumption 200mA 12V Power supply voltage 9 14VDC Weight 200g Housi...

Page 23: ...res 3 pairs recommended 1200 m 0 6 mm SYT recommended Characteristic Sensitive connection Screen Recommended To achieve 1200 m you need to install a 220 resistor at each end of the network between poi...

Page 24: ...nit ensure that a common earth is connected between the control module and the control unit If the input is set to 0V The alarm is activated opening impossible mandatory inactivation of the alarm befo...

Page 25: ...itches o Switches 1 and 2 configuration of the time delay for the opening control o Switch 3 configuration of the Alarm activation inactivation output activa tion inactivation of a third party intrusi...

Page 26: ...ect use of the system caused by return currents it is essential to use and connect the non return diodes supplied with the product in accordance with the wiring diagram above Even when using an additi...

Page 27: ...of the system caused by return currents it is essential to use and connect the non return diodes supplied with the product in accordance with the wiring diagram above Even when using an additional ba...

Page 28: ...tart the product you need to register the 3 configuration cards Add Add Alarm and Delete with the reader in order to activate it To do this follow the procedure below After this stage your product is...

Page 29: ...badge with fingerprint access for several readers on the same site so as to remember the same code for each reader therefore to not repeat the addition of badges on each reader you must only use one s...

Page 30: ...the applicable legislation in the country of installation 1 Add a user with a badge plus fingerprint Present the Add badge at the same time as the badge for the user you wish to add You have 10 second...

Page 31: ...dd again and wait for the enrolment confirmation BEEP Present the Add badge at the same time as the badge for the user you want to add You have 10 seconds to present the first finger of the user to be...

Page 32: ...finger of the user to be added 3 times You have 10 seconds to present the second finger of the user to be added 3 times if you do not enrol a second fingerprint the badge added will be encrypted as fo...

Page 33: ...user to be added 3 times You have 10 seconds to present the second finger of the user to be added 3 times if you do not enrol a second fingerprint the user added will not have an alarm function Prese...

Page 34: ...rints and badges only Present the Delete badge You have 10 seconds to present one of the 2 fingers of the user to be deleted If the user is recognised he she will immediately be deleted Present the De...

Page 35: ...n order to register a new set of configuration badges This process will delete all the users fingerprints only and badges To restore to factory settings Switch off the power Press the RESET button and...

Page 36: ...een LED Reader status Flashing alternately Reader in factory configuration waiting for configu ration badges cards Add Add Alarm Delete Flashing Off Normal operation waiting for a user On Door open On...

Reviews: