Technical manual

 C1P2FXBT

 

– V1.7 

 

 

p 12/28 

 

 

Typical connection arrangement 

1)

 

Power failure door activator and electromagnetic door lock triggered by a pow-
er failure 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

  In  order  to  avoid  all  the  random  malfunctions  that  may  interfere  with  proper  use  of  the 

system caused by return currents, it is essential to use and connect the non-return diodes sup-
plied with the control unit in accordance with the wiring diagram above. 

Even  when  using  an  additional  secured  power  supply  for  locking,  which  is  separate  from  the 
control unit power supply, it is essential to follow the wiring diagram above. 

Power supply 

+12V 0V 

 

Non-return diode 

 

Summary of Contents for C1P2FX

Page 1: ...Access control C1P2FX C1P2FXBT Technical manual...

Page 2: ...Technical manual C1P2FXBT V1 7 p 2 28...

Page 3: ...dules INFX2 and OUTFX2 RS485 11 Typical connection arrangement 12 1 Power failure door activator and electromagnetic door lock triggered by a power failure12 2 Standard door activator triggered by a v...

Page 4: ...EDEN INNOVATIONS team would like to thank you for your interest as well as your confidence in our security solution We hope that you will be completely satisfied with the level of security it provide...

Page 5: ...d in accordance with the instructions for Level 2 protected environ ment of standard NF EN 61000 4 4 o This product must be installed by an approved company Incorrect installation and use may result i...

Page 6: ...9 x 6 06 x 1 81 in Operating temperature 20 C to 50 C 4 F to 122 F Control relay 1A 12V 1A 24V 2 C1P2FXBT Weight including the housing 3 kg Housing dimensions 348 x 234 x 96 mm 13 7 x 9 21 x 3 78 in O...

Page 7: ...SYT recommended Characteristic Sensitive connection Screen Mandatory Simply connect the three wires on the reader to the control unit terminal block as shown Note Do not position the control unit rece...

Page 8: ...voltage cables and specifically not close to 230 V cables or higher Note Each reader can accept a different technology e g Reader 1 in Wiegand Reader 2 in Clock Data Note If you use an external power...

Page 9: ...teristic Sensitive connection Screen Mandatory To reach 1200 m 2730 ft you must fit a 120 resistor between points A and B at each end of the network see above Attention The total length must not excee...

Page 10: ...supply from the RS485 bus Characteristic Sensitive connection Screen Mandatory To reach 1200 m 2730 ft you must fit a 120 resistor between points A and B at each end of the network see above RS485 Not...

Page 11: ...ve connection Screen Mandatory To reach 1200 m 2730 ft you must fit a 120 resistor between points A and B at each end of the network see above Attention The total length must not exceed the recommende...

Page 12: ...that may interfere with proper use of the system caused by return currents it is essential to use and connect the non return diodes sup plied with the control unit in accordance with the wiring diagra...

Page 13: ...e of the system caused by return currents it is essential to use and connect the non return diodes sup plied with the control unit in accordance with the wiring diagram above Even when using an additi...

Page 14: ...e V key To quit press C and then V 1 Main menu P 35 P 39 P 36 P 39 P 36 P 40 P 37 P 40 P 37 P 40 P 37 P 40 P 37 P 40 P 37 P 40 USER MANAGEMENT CONFIGURE READER 1 VIEW EVENTS CONFIGURE READER 2 CONTROL...

Page 15: ...ys for at least a second Continue like this until the number is complete Example To enter the number 1 You can then confirm it by pressing the V key To erase a figure press the A key Now enter the qua...

Page 16: ...to become an Administrator function allowing the enrolment of another user without even opening the control unit enclosure press the V key otherwise press C Select the badge status In service Not all...

Page 17: ...and 32 using external software like SenatorFX or SenatorFX NET It also allows you to define the communications mode RS485 MOD TCPIP to communicate with EDEN software This menu also allows you to force...

Page 18: ...ll through the different types of reader using the and keys The following types of reader are available HID Management of Wiegand protocols management of the last bits sent by the reader The number of...

Page 19: ...the relay will be activated between 1 and 255 seconds for pulse or bistable mode Allows definition of the input used for the push button Same as the push button but for the door contact Profile of the...

Page 20: ...he same way as for the time ranges for the devices Public holidays You can configure up to 32 renewable periods or not on the control unit To add a holiday or list of specific days proceed as follows...

Page 21: ...85 bus Characteristic Sensitive connection Screen Mandatory To achieve 1200m 2730 ft you need to install a 120 resistor at each end of the network between points A and B see above Note The control uni...

Page 22: ...Ethernet network C485FX MOD TCPIP Wired connection of a single control unit to the Ethernet net work MOD TCPIP For more information on these different modules please refer to the technical documentati...

Page 23: ...ta 0 LED GND Push button Door contact Conditional Input Com NC NO 12V GND B A 12V GND Power supply BUS 485 PC BUS 485 Expansion card S GND 12V Active aerial Reader 2 GND A B 12V GND Entr e3 Clock Data...

Page 24: ...o the power supply using the cables supplied with the C1P2FX C1P2FX BT ensure that you connect the on the battery to the on the power supply and the same for the d Re attach the holder and check that...

Page 25: ...Check list C1P2FX BT Serial number Connector block check Silk screen print 2 diodes Bag Screws 4 10 Allen key T2 5 Power cable red black C1P2FX Serial number Connector block check Silk screen print 2...

Page 26: ...Technical manual C1P2FXBT V1 7 p 26 28 Notes Technical Support hotline eden innovations com...

Page 27: ......

Page 28: ...Technical manual C1P2FXBT V1 7 p 28 28 Zone Commerciale et Artisanale 670 route de Berre 13510 EGUILLES France www eden innovations com...

Reviews: