Essential safety Informations
· This product is for indoor use only IP20, do not use in damp or wet locations.
· Mains voltage must be switched off before mounting, maintenance.
· This track must be installed and maintained by a suitably qualified person in compli-
ance with latest installation and safety regulations.
· Installation and operating of this Track is subject to national safety regulations.
. The manufacturer is not liable for damage caused by improper use or installation.
· Only ceiling mounted.
· Material used for ceiling fixation should be conform to the relevant building regulation.
· It is the responsibility of the installer to ensure the electrical, mechanical and thermal
compatibility of the track-system and the fittings.
· Save these instructions.
READ INSTRUCTIONS BEFORE INSTALLING
°bloc - installation manual - 1/5
Eden design bvba – Woudstraat 5a – 3600 Genk – Belgium
[email protected] T. +32(0)89 38 60 36 F. +32(0)89 38 34 35 www.edendesign.be
1. Wire section
distance power supply to track
5m 10m 15m 20m 25m 30m 40m
m
axi
m
um
p
ow
er
insta
lled
int
o
track
30W
1.5
1.5
1.5
1.5
1.5
1.5
1.5
60W
1.5
1.5
1.5
1.5
1.5
1.5
1.5
90W
1.5
1.5
1.5
1.5
1.5
1.5
1.5
120W
1.5
1.5
1.5
1.5
1.5
1.5
2
150W
1.5
1.5
1.5
1.5
1.5
2
2.5
180W
1.5
1.5
1.5
1.5
2
2.5
3
210W
1.5
1.5
1.5
1.5
2
2.5
3
240W
1.5
1.5
1.5
2
2.5
3
4
270W
1.5
1.5
1.5
2
2.5
3
4
300W
1.5
1.5
2.5
2.5
3
4
5
Always choose for a power supply with at least 10% overcapacity compared to the sum of the total
power installed in the track
.
MAX POWER
Bloc 300 14.4W
Bloc 600 28.8W
Example
- a track of 6m with 10 x bloc 300 (10x14.4W=144W)
- distance between power supply and track is 40m
in this particular case you need a 2.5mm² wire section
Wire selection & power