![EDAC EDAC9 Series Quick Start Manual Download Page 6](http://html1.mh-extra.com/html/edac/edac9-series/edac9-series_quick-start-manual_2357135006.webp)
Page 6 of 24
For Support C61-
-9
-
Or s
DOHV
@
HGDF
.com.au
Serial (RS232) Port
The RS232 Port is the primary interface for the application software and connection to external
devices. ET/AT commands are used to communicate with the terminal. The RS232 interface is
implemented as a 9-pin D-Sub socket with screw fittings.
Pin
Function
1
DCD Out
2
RXD Out
3
TXD In
4
DTR In
5
GND
6
DSR Out
7
RTS In
8
CTS Out
9
RING Out
Antenna
The E
'$&
9xxx-xxx Terminal has a standard FME M antenna Plug on the end of an approximately
110mm cable.
FME M Antenna Connector
SIM Card
The SIM card connector is located on the underside of the E
'$&
9xxx-xxx Terminal. The unit
supports both 3V or 1.8V SIMs. Any SIM card used needs to be correctly provisioned for the
services and network upon which it is intended to be used.
If the terminal is intended to be used for remote access to a device a terminating data number for
Circuit Switch Data (CSD) will need to be provisioned by the network operator, this number will
usually differ from any voice/SMS number. Other key configuration settings are;
◩
Telstra NextG® SIMs when used for CSD require 2620 bearer capability
SIM Pin
If the SIM used has a PIN either;
•
The unit can be configured to enter the SIM pin, refer configuration tool section
OR
•
The SIM PIN should be deactivated, insert the SIM in a mobile phone and deactivate then
transfer the SIM into the E
'$&
9xxx-xxx unit.
Caution
Always disconnect power supply before
inserting or removing SIM Card.
Care should be taken in inserting and
removing the SIM card so as not to
damage the SIM holder or cover.