4
ELECTRICAL WIRING:
1. Connect 120VAC supply to HI (TERMINAL 14) and NEUTRAL (TERMINAL 13).
2. Connect one side of each valve to the COMMON (TERMINAL 11),
sequentially.
3. Connect the other side of each solenoid valve to the SWITCHED OUTPUTS
(TERMINAL 1 through 10), sequentially.
4. Set OFF ADJ potentiometer to desired time between pulses.
5. Set ON ADJ potentiometer to desired time duration of each pulse.
6. Connect 120 VAC Hold-Off Circuitry if needed to TB 2.
WARRANTY
All timers come with a one year warranty against parts and/or manufacturing defects. Please see
our terms & conditions or contact us for additional details.
EVALUATION & REPAIR SERVICE
On timers older than one year, we offer a test and repair lab at our facility. Once received,
boards are logged in, evaluated and tested. A report is then sent to the customer with
repair and/or replacement options.
To send a board to us for evaluation, please call 704-545-1439 or email
to request a Return Authorization.
ENCLOSURES & ACCESSORIES
Need an enclosure for your Timer Board? We stock a wide range of enclosures and can provide
any of our Timers and Controls in an enclosure with a 48-hour turnaround available.
Enclosures Construction:
•
Mild Steel, Stainless Steel, Fiberglass
•
With and Without Viewing Windows
NEMA Ratings
NEMA 1, 4, 4X, 7, 9 and 12 environments
Mounting:
Suitable for wall mount, floor mount or free
‐
standing
Options Available with Enclosures:
•
2
‐
Way (On/Off) Selector Switches
•
3
‐
Way (On/Hold/Off) Selector Switches
•
Magnehelic Gauge mounted in door
•
Photohelic Gauge mounted in door
•
Terminal Blocks mounted inside
•
Bulk head fittings
•
Air tubing and wiring