ECTIVE SI & TSI Series
39
Caution!
Please note the maximum power of the electronic devices!
For currents >15 A electronic devices have to be connected directly to the terminal for
direct connections.
Warning!
Risk of electric shocks
The device is always equipped with security features to prevent dangerous electronic
shocks.
However, in order to ensure the highest possible safety during operation, it is impera-
tive that the inverter’s ground connection be connected to a protective earth (usually
green-yellow cable) in any case.
Operating conditions
Everything at a glance
Power indication proportional to the
continuous output indicated in %
120% – 150% for 10 seconds
150% – 200% for 2 seconds
Switching time UPS (TSI series)
<16 ms
AC voltage
230
V
AC voltage fluctuation: max. 10%
Frequency: 50
Hz ± 1Hz
Waveform
Pure sine wave (THD < 4%) at rated input
voltage
Battery types
Wet, AGM, GEL, Li-Ion (only with BMS)