S2CG electrical specifications
Table 13
Capacity Volts/HZ/PH
Fan motor
Compressor
Total
amps
Min
volt
M.C.A. HACR
BRKR
Circuit #1
Circuit #2
AMPS
HP
RLA
LRA
RLA
LRA
9900
208/230/60/1
0 .8
0 .125
3 .9
20
3 .9
20
7 .8
197
8 .7
15
9200
208/230/60/1
0 .8
0 .125
3 .9
20
5 .2
27
8 .8
197
10
15
2200
208/230/60/1
0 .8
0 .125
5 .2
27
5 .2
27
9 .8
197
11
15
S2CG
performance data: Matched with EMI AmericaSeries Indoor Units
S2CG cooling systems with two wall units
Table 14
Wall units
Condenser
Btuh
SEER
SHR
EER
Ref.
WLHG09
S2CG99
18,000
13 .0
0 .80
11 .9
R410A
WLHG12
S2CG22
24,000
13 .0
0 .72
12 .0
R410A
WLHG12
S2CG92
21,000
13 .0
0 .74
12 .0
R410A
S2CG cooling systems with two universal units
Table 15
Air handlers
Condenser
Btuh
SEER
SHR
EER
Ref.
UNHG09
S2CG99
18,000
13 .0
0 .80
11 .9
R410A
UNHG12
S2CG22
24,000
13 .0
0 .72
12 .0
R410A
UNHG12
S2CG92
21,000
13 .0
0 .74
12 .0
R410A
S2CG cooling systems with two cassette units (_
Table 16
_ = G or H)
Cassettes
Condenser
Btuh
SEER
SHR
EER
Ref.
CAH_09
S2CG99
18,000
13 .0
0 .75
11 .5
R410A
CAH_12
S2CG22
24,000
13 .0
0 .75
11 .5
R410A
CAH_12
S2CG92
21,000
13 .0
0 .75
11 .5
R410A
Specification and Dimensions