4 - MAINTENANCE

Perform general housekeeping and maintenance as 
specified below.

4.1  Continuous

•  Keep boiler area free from combustible materials, 

gasoline and other flammable vapors and liquids.

•  Keep combustion air and vent terminations (outside 

building) free from trash, vegetation and other items 

capable of blocking flow.

CHECK LIST

If a fault develops, or is suspected, call your Service 

Technician as soon as possible. Go through the following 

check list before you contact Service Agency.

• Is electricity supply on?
• Is display ON and symbols 

 

 displayed?

• Is symbol 

 displayed?

• 

Is gas supply on?

• Is main water supply turned on?
• Is system pressure correct?
• 

Are boiler temperature controls set high enough?

• 

Is room thermostat (if fitted) set high enough?

• Are radiator valves open?

4.2  Monthly

•  Inspect combustion air, vent, and condensate drain 

piping for deterioration, leaks or sagging. Contact 

qualified agency, as necessary.

• 

Inspect system piping for leaks. Contact qualified 

agency, as necessary.

•  Inspect condensate drain trap for sediment or 

blockage.  Contact qualified agency if cleaning 

required.

• 

Check air vent(s) for leakage.

• 

Follow OPERATING INSTRUCTIONS to return to normal 

operation.

 WARNING

Burn and scald hazard.  Verify Safety Relief Valve 

discharge piping run to safe discharge location before 

conducting maintenance procedure. Contact qualified 

agency to correct improper piping.

!

     

4.3  Check According to Manufacturer’s 

Instructions

Safety Relief Valve - Refer to manufacturer’s instructions.

4.4  Annually or Beginning Each Heating Season

• 

Contact qualified agency to perform maintenance and 

cleaning per Installation, Operation and Maintenance 

manual.  Inspection will include examining all flue 

product carrying areas, vent system, burner and heat 

exchanger.  

• 

Will also include filling boiler with water if drained as 

part of End of Heating Season procedure.

• 

Condensate trap may require cleaning and refilling.

4.5  End of Heating Season, if boiler not used for 

domestic hot water

• 

Follow instructions to TURN OFF GAS TO APPLIANCE. 

See section 2.

• 

Contact qualified agency to drain heating system (if 

system does not use antifreeze) and condensate trap 

if heating system is exposed to freezing temperatures 

while out of service.

 WARNING

Asphyxiation hazard.  Contact qualified agency if 

condensate trap is not filled with water.

!

     

PN 240012896 Rev. A [01/31/2020]

Summary of Contents for Utica Boilers MACF-150

Page 1: ...ier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier USER S INFORMAT...

Page 2: ...control which has been under water WARNING Fire explosion asphyxiation and electrical shock hazard Improper maintenance and service could result in death or serious injury Read this manual and underst...

Page 3: ...de central heating as required Hot water is available whenever a hot tap is open Combi models only 2 2 OPERATING INSTRUCTIONS Stop Read ALL Safety information above Set thermostat to lowest setting Tu...

Page 4: ...ater temperature adjustment to increase the temperature and to decrease it Boiler operating information Operating mode DHW DHW Heating Heating Only Off Reset Exit menu functions BUTTON Explanation 3 1...

Page 5: ...03 Indirect Tank DHW temperature boiler CH only 13 Manufacturing information 04 Domestic hot water temperature boiler with plate exchanger 14 Identification Open Therm communication 05 Water pressure...

Page 6: ...If this fault persists call authorized SERVICE technician 118 Hydraulic pressure too low Call authorized SERVICE technician 125 No circulation safety trip control performed via temperature sensor Pres...

Page 7: ...eaning required Check air vent s for leakage Follow OPERATING INSTRUCTIONS to return to normal operation WARNING Burn and scald hazard Verify Safety Relief Valve discharge piping run to safe discharge...

Page 8: ...fications subject to change without notice 2020 ECR International Inc 2201 Dwyer Avenue Utica NY 13501 Tel 800 253 7900 www ecrinternational com BDR THERMEA GROUP Name Address Phone Email Installer In...

Reviews: