8
Operation Instructions
Before operating the TigerO, make sure that the room is vacant of
People, Pets or Plants (PPP). Warning: Ozone is Hazardous gas
.
Warning: Ozone is hazardous gas!
Close all room windows and all other openings, and place the machine in the center
of the room while assuring that both air-inlet and air-outlet are not blocked!
Operation in
Local
mode:
1.
Plug the electrical cable cord in the TigerO socket and then connect
it to the electricity mains.
2.
Turn the Key-Switch to its
Normal
position (left side).
3.
Turn the Main Switch ON.
The White Light will turn ON and the Red light (Standby) will turn ON.
The air-blower will start running and air will be emitted from the outlet
mesh on the upper back side.
4.
Set the needed operation time by the Times Selector-Switch on the operation
panel.
5.
Press the Start button.
The Red light will turn OFF* and the Orange (ozone) Light indicator will
turn ON withing 2 seconds.
Leave the room immediately!
And close the door behind you.
6.
After the generation time is completed (according to the selected time),
the Orange (ozone) light will turn OFF and a "waiting period" is starting.
Note: During the waiting period the air-blower continue to run in order
to circulate the ozone and distribute it homogeneously in the room.
Do not enter the room during the waiting time.
7.
After the waiting time is completed you may enter the room and turn the Main
Switch OFF. Note: the waiting time should be about 3 times longer than the
generation time.