Ecox EIHPTC Series Owner'S Manual Download Page 2

2

EIHPTC

CEILING FLOOR TYPE

Summary of Contents for EIHPTC Series

Page 1: ...CEILING FLOOR TYPE Thank you for purchasing this ecox product Before using this machine please read this manual and retain it for future reference OWNER S MANUAL EIHPTC EIHPTC ...

Page 2: ...2 EIHPTC CEILING FLOOR TYPE ...

Page 3: ...purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail Air flow louver at air outlet Air inlet with air filter in it Installation part Display panel Remote control Drain pipe Connecting pipe Air inlet Air outlet FIG 1 1 OR 1 2 3 5 4 7 6 8 8 8 8 8 8 9 9 7 ...

Page 4: ...ted current or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire It is not good for your health to expose your body to the air flow for a long time Do not insert fingers rods or other objects into the air inlet or outlet When the fan is rotating at high speed it will cause injury Never use a flammable spray such as hair spray lacquer or p...

Page 5: ...nfluence to small children animals and plants may occur Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Do not operate the air conditioner when using a room fumigation type insecticide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensiti...

Page 6: ...r Timer indicator Operation lamp Alarm indicator PRE DEF indicator cooling and heating type or FAN indicator cooling only type MANUAL TIMER ALARM OPERATION DEF FAN Infrared signal receiver Temperature indicator NOTE DEF indicator cooling and heating type or FAN indicator cooling only type TIMER ALARM OPERATION DEF FAN Infrared signal receiver NOTE DEF indicator cooling and heating type or FAN indi...

Page 7: ...ting nearby may cause the unit to malfunction Disconnect the unit from the power and then connect the unit to the power again Push the ON OFF button on the remote control to restart operation Refrigerant Leakage Detection optional With this new technology when refrigerant leakage is detected by the outdoor unit EC if applicable will appear in the display area and a indication lamp will flash in th...

Page 8: ...door unit and remote control at least 1m away from televisions radios stereos and other similar equipment Failing to do so may cause static or distorted pictures A dirty air filter will reduce cooling or heating efficiency please clean it once every two weeks 5 2 ADJUST THE VERTICAL LOUVER When heating Adjust the louver downwards vertically Auto swing Press SWING H button the louver will swing lef...

Page 9: ... during long time usage If the air conditioner is installed in a dusty place clean the the air filter frequently If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting 3 2 10 5KW 10 000 36 000BTU h Open the air intake with the screwdriver or similar object Refer to Fig 6 1 Take out the air filter Refer to Fig 6 2 Cl...

Page 10: ...it A continuous low hissing sound is heard when the system is in operation This is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operation or defrost operation This is the noise of refrigerant caused by flow stop or flow change Symptom 4 3 Outdoor unit When the tone of operating noise changes Thi...

Page 11: ...ne l is abnormal T2 EPPROM malfu nction Indoor fan motor speed out of control Wate r leve l alar m malfunct ion Outdoor malfu nction Indoor twins communication malfunction Other malfunction of twins 2 5H ZF 0 5H Z ALARM DEF FAN TIMER OPERATION Pipe TEMP Sensor chec king channe l is abnormal T2B NO 1 2 3 4 5 6 7 8 9 10 11 Refrigerant leakage detection malfunction EC TABLE 8 1_A APPLICABLE TO INVERT...

Page 12: ...hannel is abnormal Water level alarm malfunction Refrigerant leakage detection malfunction Room temperature sensor checking channel is abnormal EEPROM malfunction Outdoor malfunction Outdoor TEMP sensor checking channel is abnormal In Outdoor unit COMM Checking channel is abnormal E1 DC motor speed out of control Outdoor unit low pressure error Eb Ed NO Fl TABLE 8 1_B APPLICABLE TO FIXED FREQUENCY...

Page 13: ...s in the refrigerating circuit Compressor is malfunctioning Voltage is too high or too low System circuit is blocked Wait for the comeback of power Switch on the power Replace the fuse Replace the batteries or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refrigerant Maintenance or change compressor Install manostat Use he...

Page 14: ...smitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation ...

Page 15: ...15 EIHPTC CEILING FLOOR TYPE ...

Page 16: ......

Reviews: