background image

5

REMOTE CONTROL

PORTABLE AIR CONDITIONER

EPOR

1

2

3

4

5

6

7

8

FUNCTION BUTTONS

TEMP DOWN Button   

Push this button to decrease the indoor temperature

setting in 1ºC(2ºF) increments to 30ºC(88ºF).
TEMP UP Button   

Push this button to increase the indoor temperature

setting in 1ºC(2ºF) increments to 17ºC(62ºF).
MODE  Button    

Each time the button is pressed, the operation  mode 

is selected in the sequence of the following: 

NOTE: 

Do not select HEAT mode if the machine you   purchased 

is cooling only type. Heat mode is not supported by the cooling 
only appliance.

SWING Button (on some models)     

Used to stop or start louver movement and set the 

desired up/down airflow direction.
RESET Button     

Once the recessed RESET button is pressed, all of the 

current settings will be cancelled and the control will 

return to the initial settings.
ON/OFF Button     

Operation starts when this button is pressed and 

stops when the button is pressed again.
FAN SPEED Button         

 Used to select the fan speed in four steps:

Some models have no MED FAN feature.
TIMER ON Button    

Press this button to activate the Auto-on time setting. 

Each press will increase the time setting in 30 minutes 

increments, up to 10 hours, then at 1 hour increments 

up to 24 hours. To cancel the Auto-on time setting, just 

press the button until the time setting is 0.0.
ECONOMY (SLEEP) Button    

Select this function during the sleeping time. It can 

maintain the most comfortable temperature and save 

energy. This function is available on COOL, HEAT or 

AUTO mode only
NOTE: 

While the unit is running under SLEEP mode, it would be cancelled 

if ON/OFF, FAN SPEED, SLEEP or MODE button is pressed.

 

            

   

  

AUTO

COOL

DRY

 

HEAT

FAN

Auto     Low     Med     High

   

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

SWING

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

RESET LOCK

1

2

4

3

6

5

7
8

9

10

11

SET TEMPERATURE(   C)

        LED

    DISPLAY

12

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

RESET LOCK

1

2

3

6

5

7
8

9

10

11

SET TEMPERATURE(   C)

        LED

    DISPLAY

12

ION

14

SWING

4

    FOLLOW

         ME

13

MODELS:

RG51B14/(C)E, RG51B16/(C)E,

RG51B18/(C)E, RG51B19/(C)E-M,

RG51B20/(C)E, RG51B31/(C)E

RG51B30/(C)E, RG51B32/(C)E

NOTE:

RG51B16/(C)E ,RG51B18/(C)E

models have no SWING feature;

RG51B18/(C)E ,RG51B19/(C)E-M,

RG51B20/(C)E models have no

LED DISPLAY feature.

RG51B19/(C)E-M model has

no MED FAN feature.

RG51B31/(C)E model ECONOMY 

button is instead

of SLEEP button.

RG51B30/(C)E model has no

MED FAN and SWING features.

RG51B32/(C)E model has 

no MED FAN, SWING and 

ECONOMY features.

9

Summary of Contents for E RG51B30/(C)E

Page 1: ...manual and retain it for future reference EPOR REMOTE CONTROL PORTABLE AIR CONDITIONER RG51B1 C EU RG51B14 C E RG51B31 C E RG51B C EU RG51B16 C E RG51B31 C EU RG51B17 C EU RG51B18 C E RG51B32 C E RG51B19 C E M RG51B20 C E RG51B30 C EU RG51B25 C E RG51B26 C EURG51B27 C ERG51B30 C E RG51B30 C EF Models ...

Page 2: ...THE REMOTE CONTROL REMOTE CONTROL SPECIFICATIONS FUNCTION BUTTONS INDICATORS ON LCD HOW TO USE THE BUTTONS AUTO OPERATION COOLING HEATING FAN OPERATION DEHUMIDIFYING OPERATION SWING OPERATION TIMER OPERATION ECONOMY OPERATION CONTENTS 4 3 5 8 7 9 8 9 13 8 10 ...

Page 3: ...ng on the receiver If other electrical appliances react to the remote control either move these appliances or consult your local dealer Use the remote control within a distance of 8 meters 26 Feet from the appliance pointing it towards the receiver Reception is confirmed by a beep LOCATION OF THE REMOTE CONTROL CAUTIONS 1 2 3 The remote controller is powed by two dry batteries R03 LR03 X2 housed i...

Page 4: ...ferent type Do not leave the batteries in the remote controller if it is not going to be used for 2 or 3 months Dispose of the old batteries in the special containers to be found in the sales outlets CAUTIONS MODELS Rated Voltage 3 0V Dry batteries R03 LR03 2 Lowest Voltage of CPU Emitting Signal 2 0V Signal Receiving Range Max 26 feet 8m Environment 5ºC 60ºC 41ºF 140ºF RG51B1 C EU RG51B14 C E RG5...

Page 5: ...etting in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto on time setting just press the button until the time setting is 0 0 ECONOMY SLEEP Button Select this function during the sleeping time It can maintain the most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only NOTE WhiletheunitisrunningunderSLEE...

Page 6: ...e FOLLOW ME function When the Follow Me function is activated the remote displays the actual temperature at its location The remote control will send this signal to the air conditioner every 3 minutes until the Follow Me button is pressed again The Follow Me function is not available under DRY and FAN mode Switch the operation mode or turn off the unit will cancel the follow me function automatica...

Page 7: ...D if applicable and LOW Nothing displays when the fan speed is selected in AUTO speed When AUTO or DRY Mode is selected there will be no signals displayed NOTE RG51B19 C E M model has no MED FAN speed feature FOLLOW ME display When pressing FOLLOW ME TEMP SENSING button in COOL or HEAT mode the remote sensing function is activated and this indicator displays TIMER display This display area shows t...

Page 8: ...it If the Auto mode is not comfortable for you the desired mode can be selected manually Ensure the unit is plugged in and power is available Press the MODE button to select COOL HEAT cooling heating models only or FAN mode Press theTEMPbuttontoset thedesiredtemperature The temperature can be set within a range of 17 ºC 62 6ºF 30 ºC 86ºF in 1ºC 33 8ºF increments Press the FAN SPEED button to selec...

Page 9: ...feature of the louver is activated The moving angle of the louver is 6º for each press Keep pressing the button to move the louver to the desired position NOTE On some models press it to initiate the Auto swing feature only If keep pressing the SWING button without releasing for 2 more seconds the auto swing feature of the louver is activated The horizontal louver would swing up down automatically...

Page 10: ...ately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display To set the Auto off time Press the TIMER OFF button The remote control shows TIMER OFF the last Auto off setting time and the signal h will be shown on the LCD display area Now it is ready to reset the Auto off time to START the operation Push the TIMER OFF button again to set desired Auto...

Page 11: ...ER ON Auto on Operation The TIMER ON feature is useful when you want the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time Example To start the air conditioner in 6 hours Press the TIMER ON button the last setting of starting operation time and the signal h will show on the display area Press the TIMER ON button to display 6...

Page 12: ...TIMER OFF display of the remote control Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF TIMER ON On Stop Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or ...

Page 13: ... theTIMER OFF button again to display 5 0h on the TIMER OFF display Wait for the remote control to display the setting temperature The timer settings TIMER ON or TIMER OFF occur according to the set sequence that is programmed to activate first ECONOMY SLEEP OPERATION Active Disable sleep function It can maintain the most comfortable temperature and save energy This function is available on COOL H...

Page 14: ......