background image

7

Installation Requirements

PLUMBING CODES

All plumbing must be completed in accordance with
national, state and local plumbing codes.

VALVE DRAIN REQUIREMENTS

Using the flexible drain hose (included), measure and
cut to the length needed.

Avoid drain hose runs longer than 10 feet.  Make

the valve drain line as short and direct as possible.

If possible, avoid elevating the drain hose.  This
could reduce the effectiveness of the flush cycle,
especially in a low pressure application.

The drain must be capable of handling a flow of 5 to
10 gallons per minute, depending on the home’s
water pressure.

The drain must be capable of handling the sediment
being flushed from the filter.

1-1/2”

air gap

Aim end of drain
hose toward center
of drain.  Tie or wire
tubing in place.

Drain grate

with 1” dia.

hole in center

FIG. 8

LAUNDRY TUB

STANDPIPE

1-1/2”

air gap

FLOOR DRAIN

1-1/2”

air gap

To drain point other

than floor drain.

Support tubing in
place as needed.

Drain

Fitting

CONNECTING VALVE TO DRAIN

Hose
Clamp

Valve Drain

Hose

In the state of Massachusetts: The Commonwealth
of Massachusetts plumbing code 248-CMR shall
be adhered to.  A licensed plumber shall be used
for this installation.

AIR GAP REQUIREMENTS

A drain is needed for sediment flush discharge water.
A floor drain, close to the Automatic Sediment Filter, is
preferred.  A laundry tub, standpipe, etc. are other
drain options.  The valve drain hose must be secured
in place, since drain water will be spraying from the
end of the hose at a high rate during flush cycles.
Leave an air gap of 1-1/2” between the end of the
hose and the drain.  This gap is needed to prevent
backflow of sewer water into the Automatic Sediment
Filter.  Do not put the end of the drain hose into the
drain.

FIG. 7

Clamp (2 -

not included)

Ground Wire

(not included)

GROUNDING INFORMATION

(for Installations on Metal Pipe)

The house main incoming water pipe is often
used to ground electrical outlets in the home.
Grounding protects you from electrical shock.
Installing the Automatic Sediment Filter may break
this ground.  To restore it, buy and install a #4
copper wire across the filter, tightly clamped at
both ends, as shown below.

IMPORTANT:

Flow rate to drain can

exceed 9 gpm at high-

er pressure.  Be sure

to secure drain hose

properly and test.

Summary of Contents for EASF1

Page 1: ...7301805 Rev A 3 12 08 EcoWater Systems LLC P O Box 64420 St Paul MN 55164 0420 How to install operate and maintain your EcoWater Systems Automatic Sediment Filter Model EASF1 OWNER S MANUAL...

Page 2: ...ctrical and electronic equipment to be disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from re...

Page 3: ...nt Filter is operated at water pressures not exceeding 100 psi and at water temperatures not exceeding 120 F provided further that the Automatic Sediment Filter is not subject to abuse misuse alterati...

Page 4: ...d complete in one carton Remove all items from the shipping carton and check against the packing list below Packing List Filter Assembly Dimensions 5 1 4 15 4 1 8 10 FIG 2 Inlet Outlet 1 NPT threaded...

Page 5: ...is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an electronic con...

Page 6: ...le the faceplate may need to be reversed turned around to face the opposite direc tion so that it does not end up against a wall or other obstruction This can be done either before or after the filter...

Page 7: ...of Massachusetts The Commonwealth of Massachusetts plumbing code 248 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment...

Page 8: ...compression fittings NOTE If your installation will use the mounting brack et position it correctly around the ASF before installing inlet and outlet fittings The bracket can not be put on after the i...

Page 9: ...before installing inlet and outlet fittings The bracket can not be put on after the inlet and outlet fit tings are installed 6 With the IN side of the water filter toward incoming water carefully tur...

Page 10: ...ose Installation Type B continued Installation Type C INSTALLATION USING THREADED PIPE FITTINGS MATERIALS TOOLS NEEDED Pipe threading tool Pipe wrenches Pipe joint compound Union fittings Pipe Nipples...

Page 11: ...AC ADAPTOR not included An optional AC adaptor P N 7302835 is available to supply 9V DC power to the electronic control instead of using a 9V battery This adaptor has 6 feet of wire One end plugs into...

Page 12: ...t for at least 2 seconds When the 2 digit display changes to show moving dashes See Figure 20 release the CLEAN button 2 Check drain hose to ensure a secure connection 3 The sediment flush sequence ta...

Page 13: ...display Each press increases the number of days by 1 When the number passes 30 it goes back to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic...

Page 14: ...ou saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF head whe...

Page 15: ...sole noid seat requires cleaning use the following procedure 1 Before shutting off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main ho...

Page 16: ...320 O Ring Valve 2 req 15 7301601 Battery 9 Volt 16 7298387 Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7...