Troubleshooting

AUTOMATIC ELECTRONIC DIAGNOSTICS

This water softener has a self-diagnostic function for 

the electrical system (except input power and water 

meter).  The computer monitors electronic compo-

nents and circuits for correct operation.  If a malfunc-

tion occurs, an error code appears in the display.
The troubleshooting chart shows the error codes that 

could appear, and the possible malfunctions for each 

code.
While an error code appears in the display, all buttons 

are inoperable except the SELECT/MENU button.  

SELECT/MENU remains operational so the service 

person can perform the Manual Initiated Electronic 

Diagnostics, see below, to further isolate the problem.

TO REMOVE AN ERROR CODE:

1

. Unplug the power supply.

2

. Correct the problem.

3

. Plug the power supply back in.

4

.  Wait for at least 8 minutes while the timer operates 

the valve through an entire cycle.  The error code 

will return if the problem was not corrected.

MANUALLY INITIATED ELECTRONIC 

DIAGNOSTICS

Use the following procedures to advance the water 

softener through the regeneration cycles to check 

operation.
Lift off the Salt Hole Cover, remove the top cover 

faceplate assembly by unlocking the tabs and lifting, 

to observe cam and switch operation during valve 

rotation.

1

.   Press  and hold SELECT/MENU for 3 seconds until 

“000” shows in the display.

2

.  The first 3 digits indicate water meter operation as 

follows:

 

 000 (steady) =  Soft water not in use, and no 

flow through the meter.

 

OPEN A NEARBY SOFT WATER FAUCET.

 

 000 to 199 (continual) =  Repeats for each gal-

lon of water passing 

through the meter.

NOTE:

  If you don’t get a reading in the display with 

faucet open, pull the sensor from the valve 

outlet port.  Pass a small magnet back and 

forth in front of the sensor.  If you get a read-

ing in the display with the magnet, unhook the 

in and out plumbing and check the turbine for 

binding (See Figure 18).

3

.  The last 2 digits in the display indicate POSITION 

switch operation as follows:

4

.  Use the RECHARGE button to manually advance 

the valve into each cycle and check correct switch 

operation.

continued on next page

Correct Switch 

Displays

Valve Cycle Status

–  –

Valve in service, fill, brining, 

backwash or fast rinse position.

–  

P

Valve rotating from one position 

to another.

FIG. 19

Motor

Turbine 

Support 

& Shaft

Position 

Switch

Sensor 

Housing

Turbine

Valve Outlet

FIG. 18

Summary of Contents for Calex 11

Page 1: ...Instructions for installation operation and maintenance of your water softener Installation and operating manual Water softener Calex 11 Calex 15 Calex 17 and Calex 22 Part No 7340095 Rev F 5 1 15...

Page 2: ...ening Capacity mol kg Salt Dose 28 4 0 42 45 1 0 84 61 7 1 63 42 9 0 64 73 4 1 4 102 0 3 6 48 7 0 73 79 2 1 54 113 0 4 13 89 0 1 2 154 6 3 4 183 1 5 6 Rated Efficiency mol kg of Salt at Min Salt Dose...

Page 3: ...il the model code See table below shows in the display Then press the SELECT MENU button to set and change to the flashing PRESENT TIME display Model Code Calex 11L 11L Calex 15L 15L Calex 17L 17L Cal...

Page 4: ...tra washing etc and you may run out of soft water before the next scheduled recharge You did not refill the storage tank with salt before it had run completely out Use one of the following two feature...

Page 5: ...um ber of days again when you return SET 97 FEATURE When this feature is set ON the unit will automatically regenerate when 97 of capacity has been used at any time of day The factory default setting...

Page 6: ...the display will be blank and the softener will not recharge When electrical power is restored 1 Check the display 2a If the present time is displayed steadily not flash ing the controller did not los...

Page 7: ...b clockwise while holding the bypass handle When the knob will not turn any more hard water is no longer being blended with treated water 4 Once the desired hardness is achieved the adjust ment knob m...

Page 8: ...water supply Although this may help keep the resin bed clean it may also release corrosive fumes that will weaken and shorten the life of some water softener electronic parts BREAKING A SALT BRIDGE S...

Page 9: ...he service cycle no water pressure at the nozzle ven turi Then holding the nozzle venturi housing with one hand turn the cap to remove it Do not lose the o ring seal Lift out the screen support and sc...

Page 10: ...g used when softener is recharging Avoid using hot water during recharges because water heater refills with hard water Increase in actual hardness of water supply Have unsoftened water sample tested R...

Page 11: ...les to check operation Lift off the Salt Hole Cover remove the top cover faceplate assembly by unlocking the tabs and lifting to observe cam and switch operation during valve rotation 1 Press and hold...

Page 12: ...the RECHARGE button and hold in for 3 sec onds RECHARGE begins to flash as the softener s valve advances from the service to fill position Remove the brinewell cover and using a flashlight observe fil...

Page 13: ...13 Water Softener Exploded View 1 4 2 3 5 6 8 7 11 9 10 16 17 Valve Assembly See Pages 14 15 for parts 14 18 19 21 20 22 24 26 25 28 27 23 13 15 12...

Page 14: ...Stem Guide Assembly Model 15L 17L 7327568 Float Stem Guide Assembly Model 22L Key No Part No Description 12 7337490 Power Supply 28V DC with Snap in Plugs for Europe UK 13 7250826 Power Cord 14 73402...

Page 15: ...15 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 74 65 75 78 84 Wear Strip Seal Cross section View 85 86 87 88 89 90 91 92 54 82 79 81 76 83 77 80 Valve Assembly Exploded View...

Page 16: ...571 O Ring 23 8 x 30 2 mm pack of 4 Key No Part No Description 7113040 Turbine Support Assembly including 2 O Rings See Key No 71 1 ea of Key Nos 72 73 72 Turbine Support Shaft 73 Turbine 74 7082053 V...

Reviews: