![ECOTRONS ALM-BR4-4.3 Manual Download Page 11](http://html1.mh-extra.com/html/ecotrons/alm-br4-4-3/alm-br4-4-3_manual_2355647011.webp)
ALM-BR4-4.3 Manual
8
Copyrights ECOTRONS LLC www.ecotrons.com
#
Upload
O2%,
Lambda,
and LSU
Temperature
PLC to ALM, PLC sends: "50 03
2000 0004 42 48"
Resolution
Units Range
ALM to PLC, PLC receives: "50 03
08 xxxx xxxx xxxx xxxx xxxx"
1
Registers
for sent
data
(sending
messages)
PLC to ALM
Request
Description
Data(byte)
ADR
50
CMD
03
Start Addr Hi
20
Start
Addr
Lo
00
No. Bytes Hi
00
No. Bytes Lo
04
CRC
CHK
Lo
42
CRC
CHK
Hi
48
2
Registers
for received
data
(responding
messages
)
ALM to PLC
Response
Description
Data(byte)
ADR
50
CMD
03
No. Data
08
O
2
% High 8-
bit
xx
O2% =((O
2
%
High 8-bit)
*256 + (O2%
Low 8-bit)) *
0.000514
– 12
%
-21%
to
21%
O
2
% Low 8-
bit
xx
Lambda
High 8-bit
xx
Lambda =
((Lambda
High 8-bit)
*256+(Lambda
Low 8-bit)) *
0.5 to
16
Lambda Low
8-bit
xx