background image

 

 

Page 10

 

 

 

 

use eco-friendly phosphate-free dishwashing detergents.  Using an anti-spotting agent such as Jet-Dry® 
or Finish® may also be useful. 
 

A word about glass shower doors… 

 
Over a few weeks you may see the existing scale slowly dissolve in your shower heads thereby 
increasing water flow. You may need to clean the inlet screen of your shower head during the first few 
weeks as mentioned previously to remove some of the scale that is being removed from your pipes.  We 
recommend that you first clean the shower of existing scale with a cleaning product that dissolves old 
scale that has built up before installation of the ecoTAC™ conditioner system. CLR or Lime Away are 
good cleaner choices for this purpose. We then recommend that you coat the walls in the shower, and 
your glass shower doors with Rainx, a commercial product used for automobile windshields. The Rainx 
allows the majority of the nano particles to be easily washed to drain. The few nano particles that are 
left can be easily wiped down because they can no longer adhere to the sides of the shower.  
 
 

 

 
MAINTENANCE INFORMATION 

 

The filter cartridge in your system will need to be replaced every 2 years or sooner if hard water scale is 
noticed.  Use only genuine ecoTAC™ Cartridges for replacement.  Use of an alternative media may 
adversely affect the performance of the system. 
 

Replacement Filters can be Obtained From Your Dealer 

Replacement Filter:    

ecoTAC™ P4R Cartridge – replace every 24 months or if hard water scale returns

 

 

Filter Cartridge Replacement Procedure: 

 

1.

 

Turn off the water supply to the system using the shut-off valves you installed on the inlet and 
outlet of the filter housing(s).  Depress the pressure release button on the top of each filter 
housing cap to allow any pressure inside the housing to escape.  Using a regular slotted 
screwdriver, remove the brass drain plug from the bottom of each white housing sump to drain 
all of the water from the housings.  Use a bucket to catch all of the water.  

 

2.

 

Unscrew housing sump from the cap using the spanner wrench (included with original purchase 
of your system).   

 

3.

 

Take out the old filter cartridge and discard it. 

 

4.

 

Scrub the bottom of the housing and cap with dish soap and warm water using a sponge or soft 
cloth.  Fill 1/3 with water and add about 2 tablespoons of household bleach.  Scrub to disinfect 
(we recommend that you use rubber gloves).  

Rinse all parts thoroughly!

 

 

5.

 

Inspect large O-ring.  The housing O-ring should be replaced at least once every 2 years or at 
each filter change if any damage to the O-ring is noted (kinked, cracked, stretched, etc.), or if any 

Summary of Contents for Protector 4

Page 1: ...er Heaters Dish Washers and Other Low Flow Rate Applications OWNER S MANUAL INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY...

Page 2: ...ant that these instructions be followed and that the system is operated within the technical specifications provided Your warranty may be voided if you fail to follow these instructions and or fail to...

Page 3: ...artridge shipped inside housing remove protective wrap before using one 1 spanner wrench two 2 3 4 quick connect shut off valve assemblies KEY COMPONENTS PARTS LIST 1 Quick Connect Shut Off Valve 2 2...

Page 4: ...otal hardness 50 grains per gallon 850 ppm pH Range 6 5 to 8 5 Chlorine max 3 ppm Hydrogen peroxide max 0 5 ppm Iron max 0 3 ppm Manganese max 0 05 ppm Copper max 1 3 ppm Hydrogen Sulfide H2S Polyphos...

Page 5: ...r How you plan to use this product will determine the location of installation In any event select an installation location with convenient access for regular filter replacements and maintenance The e...

Page 6: ...roximately 1 1 2 until it stops and turning the collar 1 4 turn clockwise to lock the fitting in place An o ring inside the fitting forms a tight seal on the pipe and teeth inside the fitting prevent...

Page 7: ...sary until all of the housing caps are connected When you are done check to be sure that the inlet and outlets of each housing are connected in the correct sequence Finally take the other quick connec...

Page 8: ...re unsure If you suspect that your water pressure will at any time exceed the maximum rating of 90 PSI 6 2 bar a pressure regulator must be installed before the system It is recommended that the press...

Page 9: ...oducts for clothes and dishwashing are recommended to achieve optimum results Modern surfactant or detergent based liquid soaps are preferred over old fashioned caustic solid soaps Water heaters Exist...

Page 10: ...le is noticed Use only genuine ecoTAC Cartridges for replacement Use of an alternative media may adversely affect the performance of the system Replacement Filters can be Obtained From Your Dealer Rep...

Page 11: ...oTAC system components are warranted by HomePlus Products Inc to be free of defects in material and workmanship for a period of one year from the date of purchase provided that your system was purchas...

Page 12: ...able to the distributor or any other person or entity for special incidental consequential or punitive damages including but not limited to property loss loss of incomes or loss of use damages arising...

Reviews: