Ecosy+ Snug 7 Manual Download Page 2

 

Page 

2

 of 

11

 

 

 

INTRODUCTION 

Wood-burning with multi-fuel option   
Item No.: Snug 7 
Size:          W470XD388XH619 (mm)     
 

SAFETY 

 
Safety is the most important consideration when using and installing your stove. If not 
installed and used correctly, a house fire could result. Installation must comply with 
relevant national and local Building Regulations and fire safety standards. 
IN THE EVENT OF A CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE 
EMERGENCY 
SERVICES. 
Your stove will be heavy, and care needs to be taken when lifting - 2 people will normally be 
required to lift. 
 

UNPACKING 

 
Your stove will have several of its components stored inside the stove itself for 
transportation. 
The main component is the flue collar; this will simply need attaching with the provided 
bolts on the top or rear of the fire. Ensure you remove the free oven glove and any small 
accessories that may be tucked away under the grate. 
 
 

INSTALLATION 

Installation of your stove must comply with relevant local and national Building Regulations 
and fire safety standards. We would always suggest using a qualified installer to carry out 
the installation of this product. The British recognised standard for solid fuel installations is 
HETAS. You can find a HETAS qualified installer in your area by going to the HETAS website 
– www.hetas.co.uk. If you are self-installing, the stove must be signed off by the local 
authority. 
 

 
 
 

Summary of Contents for Snug 7

Page 1: ...Page 1 of 11 Snug 7 Stove Woodburning With Multi Fuel Grate Option Version number 1 Issue date 14 08 2019 Model Snug 7 Stove Size W470XD388XH619MM...

Page 2: ...eral of its components stored inside the stove itself for transportation The main component is the flue collar this will simply need attaching with the provided bolts on the top or rear of the fire En...

Page 3: ...e will require a constant air supply and should not be used at the same time or in the same room space as extractor fans or any device which may draw air supply away from the stove The stove should be...

Page 4: ...n Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smok...

Page 5: ...r for a period of 1 3 minutes Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Dampers Left Open Operation with the air co...

Page 6: ...tion with other approved manufactured smokeless fuels as per the HETAS approved list http www hetas co uk find fuels Smokeless fuels AIR INLET CONTROLS The base control lever on the right controls the...

Page 7: ...ed kindling wood fires with each fire lasting around 40 minutes the second fire can be started when the stove is almost cooled down after the first A third slightly hotter medium type fire should then...

Page 8: ...put setting At high power output your stove will require refuelling approximately every hour It is important to follow these instructions in order to achieve clean burning and to maximise the efficien...

Page 9: ...the inside the air wash vent may need opening more during use If the vent is fully open and the glass is still going black it will most likely be down to poor quality wet wood The high temperature pai...

Page 10: ...int and over firing Incorrect use or installation not carried out by a registered HETAS installer will void the guarantee The only exceptions will be if the install has been signed off by your local a...

Page 11: ...Page 11 of 11 DRAWINGS Ecosy Unit 22 26 Folly farm Ramsdell Tadley RG26 5GJ...

Reviews: