ecosens EL-M10 Manual Download Page 2

INSTALLATIION: 

(see the diagram) 

 

Switch off the power. 

 

Fix the bottom on the selected position with the inflated screw through the screw holes at 

the side of the sensor. 

 

Connecting the power and the load to sensor as per the connection-wire sketch diagram. 

 

Switch on the power and test it. 

 

Connection illumination 

 

Connect L, N with power; 

Connect N, A with load. 

 

 

 

 

TEST: 

  Turn  the  LUX  knob  clockwise  on  the 

maximum.  Turn  the  TIME  knob  anti-

clockwise  on  the  minimum,  Turn  the 

SENS knob clockwise on the maximum. 

 

When  you switch  on  the  power, the  light 

will be on at once, and 5-30 seconds 

later  will  be  off  automatically.  Then  if  the  light  receives  induction  signal,  it  can  work 

normally. 

  After 5-10sec of the first detection, the light could work again. If there is no induction signal, 

the load should be stopped working within 5-15sec. 

 

Note: when testing in daylight, please turn LUX knob to 

     

(SUN) position, otherwise the 

sensor lamp could not work! 

 

NOTES

: 

  Electrician or experienced human can install it. 

 

The unrest objects can’t be regarded as the installation basis-face. 

  In front of 

the detection window there shouldn’t be hinder or unrest objects affecting 

detection. 

  Avoid installing it near air temperature alteration zones for example: air condition, central 

heating, etc. 

  For your safety. 

Please don’t open the case if you find hitch after installation. 

  In order to avoid the unexpected damage of product, please add a safe device of 6A when 

installing Microwave sensor, for example, fuse, safe tube etc. 

SOME PROBLEM AND SOLVED WAY 

  The load don

’t work: 

a. Check the power and the load. 

b. Whether the indicator light is turned on after sensing? If yes, please check load. 

c. If the indicator light does not turn on after sensing, please check if the working light 

corresponds to the ambient light. 

d. Please check if the working voltage corresponds to the power source. 

  The sensitivity is poor: 

a. Please check if in front of the detection window there is hinder that has effect on 

receiving the signals. 

b. Please check the ambient temperature. 

c. Please check if the signals source is in the detection fields. 

d. Please check the installation height. 

 

The sensor can’t shut automatically the load: 

a. If there are continual signals in the detection fields. 

b. If the time delay is set to the longest. 

c. If the power corresponds to the instruction. 

d. If the air temperature changes near the sensor, air condition or central heating etc. 