INSTALLATIION:
(see the diagram)
Shut off power.
Loosen the screw on the bottom lid,
open the wiring hole, pass the wire
of power and load through the
bottom lid.
Fix the bottom lid with inflated screw
on the selected position.
Connect the power and load wire
into
connection-wire
column
according to the connecting figure.
Put the sensor on the bottom lid, twist the screw tightly then electrify it and test it.
CONNECTION-WIER SKETCH DIAGRAM
TEST:
Turn the SENS knob clockwise on the maximum. Turn the TIME knob anti-clockwise on the
minimum, Turn the LUX knob clockwise on the maximum.
When you switch on the power, the light will be on at once, and 5-30 seconds later will be
off automatically. Then if the sensor receives induction signal, it can work normally.
After 5-10sec of the first detection, the light could work again. If there is no induction signal,
the load should be stopped working within 5-15sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
NOTES
:
The unrest objects can’t be regarded as the installation basis-face.
In
front of the detection window there shouldn’t be hinder or unrest objects affecting
detection.
Avoid installing it near air temperature alteration zones for example: air condition, central
heating, etc.
In order to avoid the unexpected damage of product, please add a safe device of 6A when
installing microwave sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY
The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light is
not turn on after sensing, please check if the working light
corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
The sensitivity is poor:
a. Please check the ambient temperature.
b. Please check if the signals source is in the detection fields.
c. Please check the installation height.
The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power corresponds to the instruction.
d. If the air temperature changes near the sensor, air condition or central heating etc.