INSTALLATION:
(see the diagram)
Shut off the power.
Loosen the connection column on the bottom of sensor, plug the
wire into connection hole, tighten the screws; unload the surface
of sensor, connect the sensor into connection box.
If you want to install it in quadrate connection box, penetrate
the setscrew into installation hole, aim at the installation hole
on connection box, then tighten the screw; if you want to install
it in circular one, you can use the same way as the quadrate,
also adjust the sensor’s position, tighten the setscrew on
surface, then the fixing arm will open automatically, fasten the
connection box.
Switch on the power then test it.
CONNECTION-WIRE DIAGRAM
(see the following Fig)
TEST:
Set
the function switch to “ON”, Turn the TIME knob
anti-clockwise on the minimum after taking the
Board-face off. And turn the LUX knob clockwise on
SUN
position (if you test it in daylight).
Switch on the power, the lamp should be on.
Set
the function switch to “OFF”, the lamp should be
off immediately,
all functions should be in “stop” state.
Set
the function switch to “PIR”, after 30sec later, it enter into working position. The lamp
will be turned on after receiving the inductor signal.20sec. Under no inductor signal
condition, the lamp should be off within 5~10sec.
Set
“LUX” anti-clockwise to minimum, after it is off when there is no inductor signal
condition, the lamp should be off in the daytime, but if you use a opaque object to cover
Sensor, the lamp should be on, then off within 5~10sec.
Note: when testing in daylight, please turn LUX knob t
(SUN) position, otherwise the
sensor lamp could not work!
NOTES:
Electrician or experienced human can install it.
The unrest objects can’t be regarded the installation basis-face.
There aren’t hinder or unrest objects effecting detection in front of the detection window.
Avoid installing it near temperature alteration zones, for example: air condition, central
heating etc.
Please don’t open the case for your safety if you find the hitch after installation.
If there are some difference between instruction and the function the product has, please
give priority to product and sorry not to inform you additionally.
SOME PROBLEM AND SOLVED WAY :
The load don’t work:
a. check the power and the load.
b. If the load is good.
c. If the indicator lamp is light or not.
d. Please check if the working light corresponds to the ambient- light.
The sensitivity is poor:
a. Please check if in front of the detection window there is hinder that effect to receive
the signals.
b. Please check the ambient temperature.
c. Please check if the signal source is in the detection field.
d. Please check the installation height.
e. If the moving orientation is correct.
The sens
or can’t shut off the load automatically:
a. If there is continual sensor signal in the detection field.
b. If the time-delay be set to the longest.
c. If the power correspond to the instruction.
d. If the temperature change near the sensor.Such as air condition, central heating
etc.