ecosens ECO-14 Manual Download Page 2

 

INSTALLATION: 

(see the diagram) 

 

Shut off the power. 

 

Loosen the connection column on the bottom of sensor, plug the 

wire into connection hole, tighten the screws; unload the surface 

of sensor, connect the sensor into connection box. 

 

If  you  want  to  install  it  in  quadrate  connection  box,  penetrate 

the  setscrew  into  installation  hole,  aim at  the  installation  hole 

on connection box, then tighten the screw; if you want to install 

it in circular one, you can use the same way as the quadrate, 

also  adjust  the  sensor’s  position,  tighten  the  setscrew  on 

surface, then the fixing  arm will open automatically, fasten  the 

connection box. 

 

Switch on the power then test it. 

CONNECTION-WIRE DIAGRAM 

(see the following Fig) 

 

TEST: 

 

Set 

the  function  switch to “ON”,  Turn the  TIME knob 

anti-clockwise on the minimum after taking  the 

Board-face off. And turn the LUX knob clockwise on 

SUN 

position (if you test it in daylight). 

 

Switch on the power, the lamp should be on. 

 

Set 

the function switch to “OFF”, the lamp should be 

off immediately, 

all functions should be in “stop” state. 

 

Set 

the function switch to “PIR”, after 30sec later, it enter into working position. The lamp 

will  be  turned  on  after  receiving  the  inductor  signal.20sec.  Under  no  inductor  signal 

condition, the lamp should be off within 5~10sec. 

 

Set 

“LUX”  anti-clockwise  to  minimum,  after  it  is  off  when  there  is  no  inductor  signal 

condition, the lamp should be off in the daytime, but if you use a opaque object to cover 

Sensor, the lamp should be on, then off within 5~10sec. 

Note: when testing in daylight, please turn LUX knob t  

 

(SUN) position, otherwise the 

sensor lamp could not work! 

NOTES: 

 

Electrician or experienced human can install it. 

 

The unrest objects can’t be regarded the installation basis-face. 

 

There aren’t hinder or unrest objects effecting detection in front of the detection window. 

 

Avoid installing it near temperature alteration zones, for example: air condition, central 

heating etc. 

 

Please don’t open the case for your safety if you find the hitch after installation. 

 

If there are some difference between instruction and the function the product has, please 

give priority to product and sorry not to inform you additionally. 

SOME PROBLEM AND SOLVED WAY : 

 

The load don’t work: 

a. check the power and the load. 

b. If the load is good. 

c. If the indicator lamp is light or not. 

d. Please check if the working light corresponds to the ambient- light. 

 

The sensitivity is poor: 

a. Please check if in front of the detection window there is hinder that effect to receive 

the signals. 

b. Please check the ambient temperature. 

c. Please check if the signal source is in the detection field. 

d. Please check the installation height. 

e. If the moving orientation is correct. 

 

The sens

or can’t shut off the load automatically: 

a. If there is continual sensor signal in the detection field. 

b. If the time-delay be set to the longest. 

c. If the power correspond to the instruction. 

d. If the temperature change near the sensor.Such as air condition, central heating 

etc. 