IMPORTANT SAFETY INSTRUCTIONS

 

PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING. 

 

WARNING!  

This dehumidifier is intended for domes+c and light office use only.  Any other 

use is not  recommended by the manufacturer and may cause fire, electrical shocks or other 
injuries to person or property. 
 

When using electrical appliances, basic safety precauBons should always be followed: 

 

1.  

Do not operate the dehumidifier where there is a damaged cord or plug or a:er it ons 
or it has been dropped or damaged in any way.  Arrange for the dehumidifier to be examined 
or repaired by an authorised technician.  

2. 

Always keep the dehumidifier in an upright posi+on to avoid any damage.  Place the dehumidi-
fier on an even level surface during opera+on.  

3. 

Ensure the household voltage matches the rated specifica+on for the dehumidifier before use.  

4. 

Operate this dehumidifier in an ambient temperature between 34°F and 95°F.  

5. 

Ensure that the air inlets and outlets are not blocked or covered.  Do not insert fingers or any 
objects into the air inlet or outlet openings. 

6. 

Do not place the unit too close to curtains or other objects, keep minimum distance of 8”. 

7. 

When using the "LAUNDRY" mode to dry wet clothes efficiently, keep the laundry at a safe dis-
tance from the dehumidifier to prevent water from dripping onto the dehumidifier.  

8. 

Never  place  anything  on  top  of  the  dehumidifier  and  do  not  cover  while  in  use  or  before  it 
cools down. 

9. 

To  protect  against  electrical  shocks,  do  not  immerse  or  spray  the  dehumidifier  or  any  of  its 
parts in water. 

10.  Never unplug the power cord without switching OFF the dehumidifier first.  

11.  Always unplug the dehumidifier when not in use or when moving loca+on.  To disconnect the 

dehumidifier from the power supply, grip the plug and pull from the power socket.  Never pull 
by the cord.  

12.  Always empty the water tank before storing the unit away.  

13.  Close  supervision  is  necessary  when  the  dehumidifier  is  used  in  the  presence  of  children  and 
 

pets.  

14.  Do not run power cord under carpe+ng, or cover with rugs or runners.  Arrange the cord away 

from areas where it may become a tripping hazard. 

15.  Never operate or store the dehumidifier in direct sunlight.  

16.  Repairs must be carried out by an authorised technician, failure to do so may cause damage to 

the dehumidifier or injury to persons or property and void the warranty.  Always insist on origi-
nal spare parts. 

17.  Avoid the using of an extension cable as they may overheat and cause a risk of fire.  

18.  Do not use the dehumidifier without the air filter.  Clean or replace the air filter regularly. 

19.  Dispose of the water collected from the dehumidifier, this water is not drinkable. 

20.   Do not leave the dehumidifier una5ended in con+nuous drainage over a long period of +me. 

21.  At the end of its working life dispose the dehumidifier responsibly, in accordance with local by 

laws. 

22.

 

Do not remove the water tank when running, this may cause water to leak. 

 

23.

 

This  dehumidifier  is  equipped  with  a  safety  +p-over  technology  switch.    If  the  dehumidifier  is 
+pped over it will cally switch off.

 

This dehumidifier is not intended for use by persons (including children) with reduced physical, sen-

sory or mental ces, unless they have been given supervision or on concerning use of 

the dehumidifier by a person responsible for their safety.  Children should be supervised to ensure 

that they do not play with the dehumidifier. 

READ & SAVE THESE IMPORTANT SAFETY INSTRUCTIONS FOR FUTURE REFERENCE 

Summary of Contents for DD122EA CLASSIC

Page 1: ...DD122EA CLASSIC FOR MORE LANGUAGES PLEASE VISIT www ecoseb com userguide US CA ...

Page 2: ...niture musical instruments and artwork by drying it out too much HIGH HUMIDITY High humidity indoors causes damp and condensa on The damp le by condensa on can damage plaster wall paper furniture vehicles mber windows doors and clothes It can be harmful to our health when bacteria thrives causing mould and fungus MAINTAINING SAFE LEVELS OF HUMIDITY It is important to maintain a consistent humidity...

Page 3: ...MAL or TURBO modes 4 Louvre Se ng Control Key Select from UP FRONT WIDE or HOLD 5 Timer Key Select from 2 or 4 or 8 hours mer on 6 Ionizer Key Select IONIZER for cleaner air 7 Check Indicator Indicator lights up when the unit needs a5en on 8 Water Full Indicator Indicator lights up when the water tank is full or incorrectly installed CONTROL PANEL 8 7 6 5 4 3 2 1 BACK FRONT ...

Page 4: ...he hu midity down to 40 45 RH to con trol problem areas quickly STEP 4 DRY MODE STEP 5 LAUNDRY MODE Use for drying clothes The dehumidifier will con nuously dry the air un l you switch to one of the Dry Modes It typically takes 2 4 hours to dry your laundry Normal Use Normal Laundry mode to dry your laundry at low energy saver opera on Tip Use during summer me Turbo Use Turbo Laundry mode to dry yo...

Page 5: ...lug from the socket Move the unit to an other room a er it cools down or when condi ons allows follow Steps 1 and 3 USEFUL INFORMATION When you first use the dehumidifier and peri odically therea er you may no ce a smell coming from the dehumidifier This is caused by the Zeolite desiccant material and is NOT a sign that the dehumidifier is faulty nor is it harmful to humans or pets Odour will reduce g...

Page 6: ...tank with clean water if needed Do not use detergent solvent abrasive or hot water to avoid damaging the dehumidifier Do not remove or damage the float in the water tank or the unit will not operate properly The Water Full light indicator illuminates if the water tank is not correctly in posi on Do not lt the dehumidifier when removing the water tank You may use a hose with an inner diameter of 7 16 ...

Page 7: ...giene standards The frequency depends on the dura on and condi ons of opera on To purchase a replacement filter please visit www ecoseb com STEP 3 CLEANING YOUR DEHUMIDIFIER 1 Turn the dehumidifier OFF wait for the fan to stop and unplug the unit from the socket 3 Dry thoroughly with a towel a er cleaning 4 Empty the water tank by sliding out from the side Allow water tank to drip dry or dry with a ...

Page 8: ...st 11 Always unplug the dehumidifier when not in use or when moving loca on To disconnect the dehumidifier from the power supply grip the plug and pull from the power socket Never pull by the cord 12 Always empty the water tank before storing the unit away 13 Close supervision is necessary when the dehumidifier is used in the presence of children and pets 14 Do not run power cord under carpe ng or co...

Page 9: ...ater tank or re install correctly Water float out of posi on Restore water float back into posi on Water Leaking Dehumidifier on uneven surface or water tank fi5ed incorrectly Ensure the dehumidifier is on a flat even sur face use a spirit level to check remove tank and replace correctly Filter clogged Clean or replace filter Damaged water tank Remove the water tank fill with water and place on a hard eve...

Page 10: ...allowed by law but not less than two years EcoSeb shall not be liable for consequen al or incidental damages such as property damage and incidental expenses resul ng from any breach of this wri5en limited warranty or any implied warranty Some States and provinces do not allow the exclusion or limita on of incidental or consequen al damages or limita ons on the dura on of implied warran es so these...