background image

 

Range 2 

– MB04 

Operating instructions

 

 

TRIONYX | Date du document : 18/04/2019 – Version : 01 

 

 
 
 

Instruction manual 

For safety cabinet

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Model MB04 

Summary of Contents for MB04

Page 1: ...Range 2 MB04 Operating instructions TRIONYX Date du document 18 04 2019 Version 01 0 Instruction manual For safety cabinet Model MB04 ...

Page 2: ...ONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 4 9 Recycling Page 4 10 Warranty Page 5 11 Control sheet for the user Page 6 ...

Page 3: ...centers for versatile storage Leakproof 2 51 mm bottom sump Dual vents with flame arresters 4 self leveling feet Grounding connector External dimensions H 610 x W 430 x D 430 mm Internal dimensions H 465 x W 345 x D 360 mm Storage capacity 15 liters Retention capacity 6 liters Loading capacity 159 KG per shelf Weight 30 KG 3 INSTALLATION AND COMMISSIONING Installation The safety cabinet has to be ...

Page 4: ...the loading capacity per shelf of 159 KG The cabinet also has an integrated retention tank which has a retention capacity of 6 liters 5 STORAGE Your safety cabinet is exclusively destined to store chemicals in laboratories industries schools in closed containers It must not store high concentrated corrosive products We remind you that the storage of corrosives can alter the quality of your safety ...

Page 5: ...ded 7 SAFETY CONTROLS Your safety cabinet is a safety equipment As to guarantee its perfect efficiency you have to check the equipment regularly Daily safety controls Check if the products liquids powders have flowed in the containment sumps If it has they have to be emptied and cleaned promptly with suitable equipment absorbent mat Check that the cabinet and its internal equipments are not corrod...

Page 6: ...ouse The spare parts are under 3 months warranty upon their settlement The warranty cannot be applied in the following cases The equipment has not been stored used or maintained in accordance with the standards by the user In case of a damage of the equipment by the user or a third party The equipment had a modification or a repair by the user or a third party without any prior written authorizati...

Page 7: ...y The locking system of the doors works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The containment sump is clean Remarks Date By Signature ...