background image

 

Range 14 

– A1T 

Operating instructions

 

 

ECOSAFE | Date du document : 19/06/2019 – Version : 01 

 

It has to be lifted only by suitable equipment (suct

ion cup, strap…). It has to be carried in a vertical position, and it must not be lying.  

It is imperative not to tilt the cabinet when it is carried. Indeed it can cause damages that can alter the right functioning of the cabinet.  

On the other hand, if it has to be moved, the cabinet has to be placed on a pallet and strapped, as to avoid any fall.  

 

Commissioning 

 

After having unwrapped the cabinet, ensure that you also received a set of two keys.  

Your safety cabinet has to be installed, used and maintained as to guarantee the users protection.  

 

4.  INTERNAL EQUIPMENTS 

 

The cabinet is provided with 4 retention shelves. The retention capacity per shelf is 5 liters.  

Take care not to exceed the loading capacity per shelf of 50 KG.  

 

5.  STORAGE 

 

Your safety cabinet is exclusively destined to store low risk chemicals in laboratories, industries, schools

… in closed containers.  

It must not store high concentrated corrosive products or very flammable products.  

We remind  you  that  the  storage  of corrosives  can  alter  the  quality  of  your safety  equipment.  On  the  other  hand,  we  remind  you  that 

damages due to a bad use of the equipment and in particular to corrosion won

’t be covered by our warranty.  

 

6.  VENTILATION 

 

We highly recommend connecting your safety cabinet to a ventilation system, as to evacuate the eventual vapors contained in it.  

The air renewal has to be at least 10 times the volume of the cabinet, per hour. Moreover, ensure that the ventilation runs 24h/7.  

 

Connection to a ventilation system 

The air inlets are situated at the bottom, on the door ; the outlet is situated on the top. See the schema below.  

Summary of Contents for A1T

Page 1: ...Range 14 A1T Operating instructions ECOSAFE Date du document 19 06 2019 Version 01 0 Instruction manual For safety cabinet Model A1T ...

Page 2: ...ONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 5 9 Recycling Page 5 10 Warranty Page 5 11 Control sheet for the user Page 7 ...

Page 3: ...25 x W 560 x D 545 mm Storage capacity 120 liters Retention capacity 20 liters Loading capacity 50 KG per shelf Weight 80 KG 3 INSTALLATION AND COMMISSIONING Installation The safety cabinet has to be installed on a flat surface that can bear its weight with the products inside Ensure that the safety cabinet is correctly wedged as for the cabinet not to topple The eventual blocking has to be done b...

Page 4: ...acity per shelf is 5 liters Take care not to exceed the loading capacity per shelf of 50 KG 5 STORAGE Your safety cabinet is exclusively destined to store low risk chemicals in laboratories industries schools in closed containers It must not store high concentrated corrosive products or very flammable products We remind you that the storage of corrosives can alter the quality of your safety equipm...

Page 5: ... a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at least 5 times the volume of the location per hour The cabinet itself...

Page 6: ...respect the national and local waste disposal terms Those elements should not be mixed with household waste 10 WARRANTY Your equipment holds a 12 months warranty against every manufacturing defect limited to ordinary conditions of use from the date indicated on the delivery note Our warranty can be applied only in case of manufacturing defects or hidden fault The warranty covers only the replaceme...

Page 7: ...n 01 6 In case of a bad installation of the equipment In case of damage caused by the corrosion The activation of the warranty won t extend the term Our warranty stops if the customer has not notified us in a 7 days term after seeing the fault date that the customer has to prove ...

Page 8: ...ectly The locking system of the doors works correctly The mechanic ventilation system is running correctly The ventilation system is not obstructed The air outlet is clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The shelves and the containment sump are clean Remarks Date By Signature ...

Reviews: