CLEANING
Depending on conditions, your Voyager will require periodic cleaning of certain internal components every
one to three months.
To perform proper cleaning, remove the Ozone Plate Assembly as shown
(see Disassembly, page 7).
Target Clean the target by gently removing dust with a small, soft brush.
UV Bulb The UV bulb should be gently wiped with a soft, dry cloth. Avoid handling
the UV bulb more than necessary.
Purification Plate The top area of the Purification Plate can be cleaned with ammonia or alcohol and a cotton
swab. Do not use water. Allow to dry thoroughly.
Case Clean the exterior case of your Voyager with a soft cloth dampened (not wet) with water. Do not use
harsh chemicals or solvents.
Fan/Interior of unit The interior and fan may be cleared of dust using canned air suitable for electronics.
NOTE: See page 8 for detail views of components.
TROUBLESHOOTING
WARNING:
Under no circumstances should your
Voyager unit be operated while any part of the case
is damaged, missing, or disassembled. If the case is
damaged, return your unit for repair or replacement.
Direct exposure to the internal UV light may
cause eye damage.
UV
bulb
or
OZONE
may
not
be
working
• Press the PURIFIER button to turn the Purifier function
ON.
• Remove the Ozone Plate Assembly, clean, and reinstall
(see Disassembly and Cleaning)
Unit
does
not
operate/the
OZONE
does
notoperate/all
LEDs
off
• If cleaning and reinstalling does not correct the
problem, replace the Ozone Plate Assembly (service
kit #9950159).
• Unplug and reinsert the adapter plug and
adapter to check where the power supply is plugged
in to be sure it has power.
• When looking through the rear inlet vents in low light
you should see a slight bluish glow. If there is no glow
replace the Ozone Plate Assembly
• If using the 12VDC car adapter, remove
the fuse by unscrewing the end of the adapter and
check to see if it is blown. Replace it with the same
type and rating fuse only (see Specifications). If the
fuse is not blown, check the outlet for proper
voltage.
Lack
of
air
flow
• Make sure the intake vents are not blocked and the
front of the unit is clear.
• Check to see if the fan is operating (if not, see
above).
If your unit fails to operate properly after performing troubleshooting, contact your
VOYAGER