CAUTION

 

 

RISK OF ELECTRICAL 

SHOCK DO NOT OPEN

 

ATTENTION

 

Caution:

 

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO 

NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED SERVCE PERSONNEL.   

 

This  “bolt  of  lightning”  indicates  that  uninsulated  material 
within your unit may cause an electrical shock. For the safety 
of everyone, do not remove product covering. 

 

Summary of Contents for Ozone Blaster 2

Page 1: ...laster 2 By EcoQuest 3500 7000 mg hr Ozone Generator Commercial Air Purifier OWNER S MANUAL Please read all of the information provided in this owner s manual before operating your new Commercial Air purifier ...

Page 2: ... OF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVCE PERSONNEL This bolt of lightning indicates that uninsulated material within your unit may cause an electrical shock For the safety of everyone do not remove product covering ...

Page 3: ...logy developed specifically to reduce odors and smoke in unoccupied spaces ideal for treatment of homes offices automobiles boats and More Model Ozone Blaster 2 Rated Voltage Europe AC 220 240V 50 60Hz USA Japan AC 100 120V 50 60Hz Power Consumption 100W Ceramic Plate Size 2 plates 90X50MM Air Volume Max 100 CFM 2 8 M3 min Active Oxygen on 3 5 7 0 g h Sound Level DB 45 Db Product size mm W210xH180...

Page 4: ...one Blaster 2 Front View Timer Control Knob Turn clockwise to set the timer for timed operation up to TWO hours Indicator Light Illuminates when unit is in operation High low switch ozone high and low change over switch ...

Page 5: ... Back View Fuse Holder Houses removable fuse Two amp 0 79 inch in length Power Cord Grounded cord ...

Page 6: ... will then shut the purifier off To operate the Ozone Generator Air Purifier Close off the desired area to be treated Remove all occupants and pets Position the unit as close as possible to the odor source In such environments as motels that have individual heating and cooling systems turn the fan on and set on re circulate Set timer to desired time and leave the room ...

Page 7: ...nt after 6000 hours of operation How to replace the ozone plate 1 Turn the unit off and unplug from outlet 2 Use a screwdriver to unfasten cover screw and remove cover 3 Pull ceramic plate out of ozone generator module 4 Install ceramic plate as shown in above figure be careful not to drop the plate ...

Page 8: ...y This device is warranted to be free from all defects in material in normal use for a period of 1 year from date of purchasing The warranty is granted only to the original purchaser This warranty provides for the repair or replacement of the unit replacement product or parts may included re manufactured or refurbished parts or components This warranty does not cover part of the unit that requires...