Maintenance

Heat pump water heater is a high automatic equipment, please perform regular inspection

termly. If the unit can be long-term and efficiently maintenance, the operating reliability

and service life will have an unexpected increase.

1.The extra water filters should be cleaned regularly to ensure clean water quality of the

   system,  and to avoid damage caused by dirty water filter blocking.

2.Users should pay attention for usage and maintenance to below : all units' protection

   devices are set up before leaving factory, do not make any adjustment by yourself.

3.Frequently check the power supply and electrical wiring system is solid or not, whether

   electrical components are abnormally working, if yes, should timely maintenance and

   change for a new one.

4.Perform regular checks of the water supply system, check whether the tank safety valve,

   liquid level controller and exhaust devices work properly, so as to avoid air into the system,

   and reduce the water cycle volume, thus affect the heating function and operation reliability.

5.Check whether pumps and water valves are normal working or not, whether water tubing

   and water pipes connector are leakage or not.

6.The unit and around should remain clean, well-ventilated. Regularly clean (1-2 month)the

   side air heat exchanger to maintain a good effect of heat exchange.

7.Frequently check whether each part of the unit work  normal or not, check whether there is

   oil on the pipeline joints and  charging valve  to ensure that no refrigerant leakage.

8.Do not piling up debris around the unit, so as not to block from air inlet and outlet, the unit

   around should be kept clean the dry, well-ventilated.

9.If the unit stops for a longer time, should drain all the water in the pipeline, cut off power

   supply, and sets the protective equipment.When re-run the unit, complete inspection is a

   must before reboot.

10.When unit failure, and the user can not resolve the problem, please call our Company in

   local maintenance department, in order to promptly send people for maintenance.

11.Host condenser cleaning.We propose to use 50

-60

, and 15% hot phosphoric acid for

   condenser cleaning, launch the  circulating pump of the host unit for three hours'  cleaning,

   finally rinse with water three times. (Propose to back up a 3-way connector when installing

   the pipeline, block one joint),in order to clear the connection pipe. Do not use corrosive

   cleaning fluid for condenser cleaning.

12.Water tanks need to remove theWater scale after some time (normally two months,

   according to the water quality of local place).

.Maintenance

Water heater

17

Summary of Contents for SWBH 26

Page 1: ...Installation Instruction Manual HIGH TEMP HEAT PUMP WATER HEATER...

Page 2: ...e installation Product Introducing 2 Work principle 3 Performance Data 4 Dimension 5 Operation introductions 6 Appendix 11 Wire Circuit Diagram 12 Installation instructions 13 Maintenance 17 1 CONTENT...

Page 3: ...onents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water or...

Page 4: ...city to get heat from ambient air but are also able to combine using with solar equipment will not cause pollution and no poison gas exhausting All Round The Year Hot Water Heat pump water heaters are...

Page 5: ...ation the low pressure compressor refrigerant gas inhalation in the compressor after working through the compressor a high temperature and high pressure of the refrigerant gas from the compressor to e...

Page 6: ...V Ph Hz Input power kw heat up water heat up water Running current A Thermostat factory setting Thermostat maximum setting Water connections inch Compressor quantity Fan motor quantity Fan motor inpu...

Page 7: ...The dimension for high temp heat pump water heater Dimension Water heater 5 710 685 704 750 1450 1260 160 165...

Page 8: ...ay not be suitable for all model As the model update frequently some operation may not be the same as instructed in this manual Please refer to the controller operation instruction Operation Fig 1 1 2...

Page 9: ...Fig 3 Button is applicable to electric heating function Note The shows on screen means the operating mode for water pump compressor and electric heating the means the water pump is running the means t...

Page 10: ...Fig 5 Under standby mode or operation mode press once screen show as Fig 5 then and both blink press again blink then press or to set hour of timing start press again blink press or to set minute of t...

Page 11: ...16 17 18 19 20 1 12Min 0 no display 1 yes 40Min 7 13 5 5 5 80 50 8Min 1 Auto 0 manual 1 Auto 30 90Min 8 28 12 25 80 30 0 2 30 2 15 65 80 40 55 0 127 9 99 9 99 0 127 9 99 9 99 9 99 0 regular 1 special...

Page 12: ...air exhaust temp sensor failure System 1 air exhaust too high protect System 2 air exhaust temp sensor failure System 2 air exhaust too high protect PP 5 PP 8 PP 9 EE 1 EE 5 EE 2 EE 6 EE 3 EE 4 EE 8 P...

Page 13: ...rameter 10 C When 5 C ambient temp 15 C Set point temp Data of Parameter 9 Data of parameter 9 data of parameter of 10 15 5 Ambient temp 5 For example when ambient temp is 18 deg c Parameter 9 data is...

Page 14: ...ONTACTOR R R S T N P1 P2 HIGH TEMP WATER HEAT PUMP WIRING DIAGRAM Phase Protector 1 2 3 4 5 6 7 8 Second set point switch Long distance demand high pressure switch System 1 high press switch System 2...

Page 15: ...to the distance between the barriers shown in below picture pay attention to arrow direction Water tank Water tanks should be placed where ambient temperature is above 0 Can be installed outdoors or...

Page 16: ...llation All the pipeline tubing should be matched as shown on the manual and in accordance with national corresponding construction standards Installation of water pipes should be straight and flat pi...

Page 17: ...eters valves water flow switch are safe and correct 1Check if having opened all the valves that should be opened and having closed all valves that should be closed 1Check if all necessary attemperator...

Page 18: ...least 2 minutes 1 When water pump is on and the high level switch cut off if water temperature set Temperature 5 degrees shut down water supply for tanks If water tank temperature temperature 2 degree...

Page 19: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal...

Page 20: ...High Temp Heat Pump Water Heater...

Reviews: