9
4.2. INSTALLATION DIAGRAM
The diagram below shows the correct order of connecting devices in the system.
ECOPERLA SOFTOWER CONNECTION DIAGRAM
Diagram 1.
•
The quality of the feed water, in particular in terms of iron content, manganese content, turbidity, pH value, chlori-
des and microbial content, should comply with the quality standards for drinking water.
Treated water
Treated water
Raw water
Raw water
1
2
5
3
4
6
7
1
2
4
5
3
7
6
Waste water
1.
Inlet valve to Ecoperla Softower
2.
Mechanical water filter
3.
Ecoperla Softower water softener
4.
Bypass valve
5.
Outlet valve from Ecoperla Softower
6.
Salt container
7.
Drain to the sewage system