Ecomatik DD-S2 User Manual Download Page 3

Diameter Dendrometer Small - Type DD-S2                     

                            

 

 

 

 

 
 

3. Safety Information  

The sensor is protected from rain water, but it is not waterproof. Please do not immerse 
the sensor in water, or install the sensor below a longer lasting snow cover. 

Avoid any tension between the cable and sensor during handling and operation. 

Pay attention to connections to data logger. Wrong connections will provide wrong read-
ings. 

 

4. Installation  

4.1 Cable Extension 

The standard version is delivered with 5 m cable. It can be extended up to 100 m. Cable 

type 4×0.25 mm

2

 with shield is recommended for extensions

.  

4.2 Required tools for installation and for operation 

- none - 

4.3 Mounting 

4.3.1 Select the adequate quick-mount frame size, 0 to 2.2 cm or 1.8 to 5 cm, according to 

the stem/branch diameter.  

4.3.2 Attach one end of each of the two perforated rubber belts to the fixation bolts at the 

back-side bar of the quick-mount frame. 

   4.3.3 Firmly fix the frame at the stem/branch, by tightly wrapping the rubber belts around 

the stem/branch and locking them again by slipping the desired hole of each belt on 
the corresponding bolt at the back-side bar.  

4.3.4  Unscrew  and  remove  the  two  knurled-head  nuts  from  the  dendrometer  body,  then 

insert  the  screws  into  the  slide  rail  of  the  frame  and  loosely  screw  on  the  knurled-
head nuts again.  

4.3.5 Move the dendrometer body along the sliding rail, so that the sensor rod is pushed 

in  by  about  2-3  mm,  then  lock  the  dendrometer  at  the  desired  position  by  firmly 
tightening  the  two  knurled-head  nuts.  When  the  installation  is  taking  place  shortly 
before frost period, the sensor rod should be pushed in by 5 mm. At frosts the stem 
diameter can shrink considerably. 

4.3.6 !

! IMPORTANT !!

 Fix the cable onto the tree stem/branch so that the sensor is pro-

tected from any accidental pull/ drag of the entire cable length. This can be done us-
ing a rope or cable straps. In addition, there should be no tension between the sen-
sor and cable.  

Ensure that no rain water can run along the cable, or the sensor rod and enter the 
sensor casing. Rod entrance, as well as wire outlet should hence always be inclined 
downwards. 

 

 

 