Ecomatik DD-L2 User Manual Download Page 5

Diameter Dendrometer Large 

– Type DD-L2               

                                  

 

 

 

 

 

6. Adjustment and maintenance  

Ensure that no falling branches, fruits or snow land on the sensor. The sensor is protected 
against water droplets but is not waterproof. 

When the sensor is correctly installed, it will function under outdoor conditions without the 
need for further maintenance.  

Depending on the growth rate of the tree, the sensor should be reset after some months 
or years of measurements. When the output approaches 25 mm, the sensor needs to be 
reset. 

Relax the screw slowly so that the sensor rod is pushed in by about 2-3 mm. When the 
reset is taking place shortly before frost period, the sensor rod should be pushed in by 5 
mm. At frosts the stem diameter can shrink considerably. 

Tighten all screws firmly.

 

 

 

7. Technical Specifications  

Name of the Sensor  

Diameter dendrometer large  
Type DD-L2  

Use area  

For measuring diameter growth fast growing of trees 

Suitable for plant size  

Diameter 3-30 cm  

Range of the senor 

25.4 mm   

Resolution 

The resolution of the sensor itself is infinite. The resolution of 
readings is determined by connected data logger, e.g.  
CR1000: 3.3 µm 
Dendrometer logger DL18: 0.5 µm 

Accuracy 

Dendrometer dependent: 
Max. ±1.97% of reading (stable offset) 
 
Dependent on the connected data logger, e.g.:  
CR1000:±(0.04% of 10µm) 
Dendrometer logger DL18: ±0.1% 

Temperature coeffi-
cient of the sensor  

<0.2 µm / °C in the whole range 

Linearity  

<0.7% 

Environment   

Outdoor condition: -25 to 70

C air temperature, 0 to 100% relative 

air humidity   

Weight of the sensor  

33 g without cable 

Power supply  

Stabilized Vex 0.5 

– 10 VDC, power consumption practically zero 

Material 

Stainless steel and Aluminium 

Cable length 

5 m, extendable up to 100 m  

 