background image

25

the battery module into the phone until the retaining spring audibly clicks in place. Mount the

charging socket cover (

x.

com

 50x –Ex) respectively the safety plug (

x.

com

 60x –Ex) 

7.1.3  Charging the battery

Your phone is supplied with power via a rechargeable battery. Before a new battery 

can be used for the first time it must have been charged for at least 4 hours. The 
full battery performance is only obtained after a few operating cycles.
If the battery charge level falls below the operating value, the phone will indicate 
this (the empty battery symbol flashes). When this appears charge the battery for at 
least 15 minutes before making any other calls, in order to prevent your call from 
being interrupted.

Proceed as follows to charge the battery:

Connect the charger to a wall outlet.
Insert the end of the charging plug into the designated charging socket.
The phone‘s battery will now be charged. The battery symbol indicates  that the 
battery is being charged. When the battery is fully charged the  charging process 

stops automatically. Remove the  

charging plug from the phone. 

Batteries can become warm during the charging process. This is a normal occurrence.

NOTE

-  There is a risk of explosion if the battery is not exchanged properly or if it is exposed to a 

flame. 

- Do not short-circuit the battery.
- The battery does not contain any parts that can be exchanged.
- The casing of the battery should not be opened under any circumstances.
- Only use ecom charging accessories (see point 4).
-  The use of other chargers or batteries is not permitted. If such items are used, your  

Ex-protection will expire.

- Used batteries are to be disposed of properly.

Summary of Contents for x.com 500-Ex

Page 1: ...x com 500 501 Ex x com 510 511 Ex x com 600 601 Ex x com 610 611 Ex Safety instructions...

Page 2: ...the battery 24 7 1 3 Charging the battery 25 7 2 Safety information 26 8 Repair 26 9 EC Declaration of Conformity 26 10 Declaration of conformity x com 5xx Ex 27 11 EC Type Examination Certificate x...

Page 3: ...ate regulations Please read these operating and safety instructions carefully before starting to use the unit In case of any doubt in the form of translation or printing errors the German language ope...

Page 4: ...CKX 00 car charger ALX 00 The battery module may only be charged in a temperature range of 0 C 45 C Only accessories approved by ecom instruments GmbH may be used The x com 5xx Ex and 6xx Ex is not w...

Page 5: ...cloth diluted soapy water or commercially available handwash It must be ensured that the unit is not taken into zones 0 and 1 or 20 21 and 22 Only valid for model x com 60x Ex Only the original batte...

Page 6: ...T130 C II 3G Ex ic IIC T4 x com 50x Ex and x com 51x Ex Approved for zone 2 device group II explosion group IIC explosive gases vapours or mist temperature class T4 Only x com 50x Ex Approved for zon...

Page 7: ...g IP64 7 Battery 7 1 Changing the battery The AMX 5x or 6x for the x com unit may only be changed outside the Ex area The model number AMX 60 may be followed by additional letters or numbers which are...

Page 8: ...y plug x com 60x Ex not applicable for x com 51x Ex and x com 61x Ex turn the mobile phone 7 1 2 Inserting the battery Proceed as follows to insert the battery Insert the battery module with the two c...

Page 9: ...follows to charge the battery Connect the charger to a wall outlet Insert the end of the charging plug into the designated charging socket The phone s battery will now be charged The battery symbol i...

Page 10: ...ts GmbH for inspection Attention Extreme temperatures can have an adverse effect on charging the battery module AMX 5x or AMX 6x Do not dispose of the battery module in a fire Do not short circuit the...

Page 11: ...The basic health and safety requirements are met by virtue of conformance with EN 60079 0 2006EN 60079 11 2007 EN 61241 0 2006 EN 61241 11 2006 10 If the certification number is followed by an X then...

Page 12: ...C Models and classification Device type X com 50x Ex X com 51x Ex Designation II 3G Ex ic IIC T4 II 3D Ex icD 22 T130 C Ta 20 C 50 C II 3G Ex ic IIC T4 Ta 20 C 50 C Covering of the interface Interfac...

Page 13: ...Only the AMX 50 or AMX 51 battery modules may be used 4 Opening or changing the battery modules is not permitted within the explosive area 5 The interface cover of the X com 50x Ex must be firmly sec...

Page 14: ...ic health and safety requirements are met by virtue of conformance with EN 60079 0 2006 EN 60079 11 2007 EN 61241 0 2006 EN 61241 11 2006 10 If the certification number is followed by an X then this i...

Page 15: ...safe Transmitting power up to 2W permissible ambient temperature range 20 C to 50 C 16 Test report no ZELM Ex 1000724606 17 Special conditions 1 The safety instructions are to be observed 2 The devic...

Page 16: ...e and they should only be charged outside the explosive area using the corresponding charging accessory The housing protection rating for the X com 60x mobile phone is IP 64 In the future the explosio...

Page 17: ...the AMX 60 or AMX 61 battery modules may be used 4 Opening or changing the battery modules is not permitted within the explosive area 5 The interface cover of the X com 60x Ex must be firmly secured i...

Page 18: ...nschlie lich aber nicht beschr nkt auf die stillschweigende Garantie der Markttauglichkeit und der Eignung f r einen bestimmten Zweck es sei denn anwendbare Gesetze oder Rechtsprechungen schreiben zwi...

Reviews: