background image

 

 

 

© 2016 Ecolink Intelligent Technology Inc. 

 

  PN FF-ZWAVE5-ECO 

Network Inclusion/Exclusion: Key Points to Remember 

 

Controller inclusion mode must be activated BEFORE starting sensor inclusion or exclusion mode. 

 

The sensor can only be included into one controller network at a time, and must be excluded from one network before inclusion in 
another 

 

Exclusion mode on the senor is initiated following the same exact procedure as inclusion.

 

 
LED Status 

 

The FireFighter

tm

 is equipped with a multi-color LED.  The state of the LED will change based on the state of the device.  

 

Insert Battery    

= One(or two, if in CO mode below)  RED blink, then one GREEN blink 

 

Device not included 

= Green light breathing (slow blink) 

 

Learn button pressed   = Solid Yellow (red + green) while in learn mode. 

 

Sound detected  

= Flash YELLOW for the duration of the sound 

 

File Alarm Detected 

= Solid RED for 3 seconds, then blink red while tone detected 

 

Case Opened   

= Red/Green breathing until case closed (while added to a network) 

 

C0 Alarm Detection 

In addition to Smoke Alarm detection, the device can detect the presence of a carbon monoxide alarm.  By default, the 
sensor is not guaranteed to detect a CO alarm.  The device can be configured to more reliably detect a CO alarm in 
exchange for a reduced battery life.  This mode can be changed by holding down the tamper switch and learn button for 
10 seconds.  The device should then be reset ( remove battery and replace ) in order to determine the current device 
setting. 

 

RED + GREEN    

= Device will not reliably detect CO, but standard battery life 

RED + RED + GREEN  

= Device will more reliably detect CO, but with reduced battery life.   

 

  

Factory Default 

The FireFighter™ can be restored back to factory default settings which will remove its Z-Wave Plus node ID from the 
sensor (but not the controller) with the following steps.  Please use this procedure only when the network primary 
controller is missing or otherwise inoperable.  
1)

 

Put the battery into the sensor. 

2)

 

Do not press the tamper switch. 

3)

 

Hold the learn button down for 10 seconds until the LED turns RED. 

4)

 

Release the learn button and wait for the sensor’s green LED to “breath” on and off continuously. The sensor is now 
ready to be added to a Z-Wave Plus network, and all settings have been restored. 

 

 

Summary of Contents for firefighter

Page 1: ...r to the instructions provided by the manufacturer of your specific controller for details on initiating the controller s inclusion mode 1 Verify that the Z wave Plus controller you are using is compatible with the FireFightertm 2 Either mount or move the FireFightertm sensor as close as possible to the location the sensor will remain See installation section below 3 Put your Z wave Plus Controlle...

Page 2: ...larm detection the device can detect the presence of a carbon monoxide alarm By default the sensor is not guaranteed to detect a CO alarm The device can be configured to more reliably detect a CO alarm in exchange for a reduced battery life This mode can be changed by holding down the tamper switch and learn button for 10 seconds The device should then be reset remove battery and replace in order ...

Page 3: ...lease test the unit once per week to ensure proper functionality Installation The package contains the following 1 FireFighter Sensor 1 Sensor Mounting Bracket 2 Screws for Sensor Mounting Bracket 1 Adhesive tape for Sensor Mounting Bracket STEP ONE Identify Location for Sensor Determine the location of the smoke or CO detector that you require the FireFighter to detect Note that the sensor must b...

Page 4: ...it is pointed toward the smoke detector STEP TWO Mount the sensors mounting plate to a clean dry surface with the adheasive tape and or the screws provided Note the arrow should point toward the device that the FireFighter is intended to detect Slide the Firefighter onto the mounting plate Smoke Detector Microphone 6 max FireFighter Sensor ...

Page 5: ...ntended for software engineers working on Z Wave Plus controllers and home automation enthusiasts to integrate the Z Wave Plus FireFighter into their system Device Classes Generic Device Class GENERIC_TYPE_SENSOR_ NOTIFICATION Specific Device Class SPECIFIC_TYPE_NOTIFICAT ION_SENSOR Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO v2 COMMAND_CLASS_VERSION v2 COMMAND_CLASS_MANUFACTURER_SPECIFIC v2 COMM...

Page 6: ...tting Low Replace Battery Now 0x0B Battery Needs Replacing Z Wave Plus Command Class Basic For backwards compatibility with older Z Wave Plus Controllers the Basic Command Class is supported in the following manner If either a smoke alarm or a CO alarm is detected the lifeline nodes will receive an unsolicited Basic Report of 0xFF When no more smoke or CO alarm sound detected the lifeline nodes wi...

Page 7: ... hour and 1 week with interval steps of 200 seconds The sensor will also send a wakeup notification whenever the case is closed The FireFighter detector does not detect the presence of smoke heat or fire directly It relies solely on the presence of an audio alarm signal generated by an existing smoke or fire detector in proximity to the Firefighter detector to make such a determination The FireFig...

Page 8: ...a norme d Industrie Canada exempts de licence RSS Son fonctionnement est soumis aux deux conditions suivantes 1 c et appareil ne peut pas provoquer d interférences et 2 c et appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif FCC ID XQC FFZ5 IC 9863B FFZ5 Warranty Ecolink Intelligent Technology Inc warrants that for a ...