Ecolink Firefighter FFZB1-ECO Installation Manual & Users Manual Download Page 2

TESTING 

(

see 

IMAGE: 1)

 

To test the RF transmission from the mounted position you can generate a tamper by removing the cove. This will 
send a signal to the control panel. To test the audio detection, press  and hold the smoke detector test button. If 
you are using zone type 16 (Fire with Verification) you must press and hold the smoke detector button for at least 30 
seconds to ensure that FireFighter™ has had sufficient time to identify the smoke alarm pattern and lock into alarm. 
Ensure the FireFighter™ cover is on and that you wear hearing protection.   

NOTE:  

This system must be checked by a qualified technician at least once every three (3) years.  Please test the unit once 

per week to ensure proper functionality. 

 

LED

 

The Firefighter™ is equipped with a multi-color LED. When a valid audio signal is heard the LED will turn red and 
flash in sequence to the smoke detector sounder. When the Firefighter™ has determined the audio signal heard is 
a valid alarm, the LED will turn solid red to indicate it has transmitted to the panel. On power up, the LED will stay 
solid green for 2 seconds, then blink green 3 times every 5 seconds (approx.) when not enrolled with a panel. 

 

 

REPLACING THE BATTERY

 

When the battery is low a signal will be sent to the control panel. To replace the battery:

 

1.

 

Remove the top cover to reveal the battery. This will send a tamper signal to the control panel.

 

2.

 

Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as indicated on the device.

 

3.

 

Re-attach the cover, you should hear a click when the cover engages properly.

 

WARNING: While the audio detector monitors its own battery, it does not monitor the battery in the smoke 

detectors. Batteries should be changed as per the original smoke detector manufacturer’s instructions. Always test 
the audio  detector and smoke alarms after battery installation to confirm proper operation 

 
ATTENTION

: Bien que le détecteur audio surveille sa propre batterie, il ne contrôle pas la batterie dans les 

détecteurs de fumée. Les piles doivent être changées selon les instructions du fabricant original de détecteur de 
fumée. Toujours tester les détecteurs de fumée et alarmes audio après l'installation de la batterie pour confirmer 
le bon fonctionnement. 

 

          

    

 

 

                                                                                                                                                                                                                                                 

REBOOTING AND RESETTING TO FACTORY DEFAULTS 

In order to reboot the device, simply remove the battery and place it back in. Upon doing this, you should see the 
green LED illuminate. See LED section for more information on LED behavior.  
 
To reset the device to factory defaults use the following instructions: 
1.

 

Open case and remove battery from device. 

2.

 

Press and hold tamper switch.  

3.

 

Place battery back into the device while still holding the tamper switch. 

4.

 

When you see the green LED illuminate, release the tamper switch.  

5.

 

After releasing the switch, the device will restore to factory defaults.  

 

 

LEARN BUTTON

 

TAMPER SWITCH

 

 

IMAGE 1: ENROLLING / TEST / TAMPER BUTTON 

 

B

 

 

 

IMAGE 2: INSTALLATION DISTANCE

 

HOLES TO LINE

 

UP WITH EXISTING SMOKE 

DETECTOR

 

 

IMAGE 3: SIDE MARKINGS

 