Caution

•  Do NOT use any anti-bacterial cleaning agents or products inside the composting system.
•  Do NOT use sugarcane mulch or other stringy fibrous material.
•  Do NOT use bowl cover when system in use.
•  Avoid bulking agents with very fine particles that can become “cakey“ when absorbing 

moisture, which will block the drainage of excess moisture.

•  Only use peat moss, wood-shavings and hemp in your EcoLet.

Maintenance

•  Check the fluid level indicator tube regularly and adjust thermostat accordingly.

 

– Fluid level increasing and above halfway = turn thermostat up

•  Add bulking agent regularly (refer to Correct Setting on page 8).
•  Empty the compost tray BEFORE it is full.

 

– Most people empty it once a month to avoid overfilling.

When to reintroduce the microbes

You will know when the pile is not composting as the matter will not be breaking down (which 
reduces volume). This is most evident by monitoring the toilet paper, as it tends to break down 
first.

As you use the system, the microbes that you introduce will spread through your composting 
chamber which is aided by the mixing mechanism. If they are able to thrive in the composting 
chamber environment you may never need to reintroduce them. An optimal composting 
environment for these microbes is moist and warm. You will therefore want to consider 
reintroducing microbes if your system has:

•  Completely dried out. In dry conditions microbes will start to hibernate and eventually die
•  Gone septic. If your system is full of liquid the microbes will drown 
•  Becomes too cold. Microbes will slow down start to hibernate in cold temperatures 

It can also be “refreshing” for your compost pile to have some new microbes added into the 
top layers. This can be helpful if you have been using the system for a long time or if you have 
left the system unattended and turned off. 

Thankfully, there’s two really easy ways to add microbes into the composting chamber:

•  Add Nature Quick Microbes 
•  Add fully composted material (it will still contain a population of microbes)

Summary of Contents for 25e

Page 1: ...EcoLet 25e 65e Owner s Manual May 2022 ...

Page 2: ...t cross section 5 Settings 5 Installation 6 Operation 7 Caution 10 Maintenance 10 Troubleshooting 11 Contact Details We are available to chat from 8am to 5pm Monday to Friday excluding public holidays PHONE 1300 138 182 EMAIL info ecoflo com au WEBSITE www ecoflo com au www ecolet com au ...

Page 3: ...0mm L x 650mm W x 660mm H Foot print including compost drawer 1100mm L x 650mm W minimum THREE IMPORTANT THINGS TO REMEMBER 1 When the toilet is used room temperature should be at least 18 C 2 If you are away for more than two days always turn the power off and put the cover in the seat opening otherwise the compost will become dry 3 The heating element in the room can also be switched off the com...

Page 4: ...owl cover A rake The vent kit contains Ventilation pipes white pipes 6pcs x 675mm Outside pipe black 2pcs x 675mm Insulation 2pcs x 675mm Reduction coupling 55 110mm Roof flashing Insect netting Optional wall installation kit not included Extra accessories not included 30 and 45 Pipebends Insulation Additional vent piping Bulking agent peat moss hemp wood shavings Compost starter Enzymes cleaning ...

Page 5: ...ation you might have to adjust the setting depending on usage and the liquid level in the tube 28 Heater settings Set the heat according to load read the level tube 28 on the right side seen from the front Step 1 Green light Only fan is operating Step 2 One amber light Fan 50 top heater Step 3 Two amber lights Fan 50 top heater 100 bottom heater Step 4 Three amber lights Fan 100 top heater 100 bot...

Page 6: ...gh the ceiling or out through the wall and up the exterior of the building An optional vent wall kit is available Do not use bends over 45 3 Install the roof flashing and seal as required 4 Insulate all parts of the vent pipe in roof cavities or outside the building using the insulation provided and shield with 100mm pipe provided Note You may need to source extra insulation 5 Fit the insect netti...

Page 7: ...m on and turn the dial to the first position so that only the green light is on just the fan not the heater 4 Make sure that when the fan is running you don t have the bowl cover in place this acts like a plug and seals the composting chamber only when the system is not in use The mixer arm The mixer arm will turn a full revolution when switched on If you lift the seat and place it down the mixer ...

Page 8: ... Check the fluid level indicator tube on the side of the unit 28 If the liquid in the tube is increasing turn the thermostat up one click to aid evaporation The thermostat setting may vary depending on the usage patterns and climate Adjust the dial according to use Level in the liquid tube The liquid tube on the right hand side viewed from the front 28 shows how much liquid there is in the tray Th...

Page 9: ...ids When the tray slides out the liquid hose RHS 28 needs to be unplugged to remove it fully so make sure you have reduced the leachate level as low as possible The compost process takes at least three to four months so you may not see compost in the first few months If your collection tray contains only bulking agent then add it back into the composting chamber through the toilet seat If you re a...

Page 10: ... toilet paper as it tends to break down first As you use the system the microbes that you introduce will spread through your composting chamber which is aided by the mixing mechanism If they are able to thrive in the composting chamber environment you may never need to reintroduce them An optimal composting environment for these microbes is moist and warm You will therefore want to consider reintr...

Page 11: ...uid leaking onto floor Identify where liquid is coming from why is it not evaporating or being absorbed Check fluid level indicator tube on side of unit 28 If liquid is visible in the tube turn the thermostat up one click and monitor make sure bottom heater is working Ensure the vent pipe is well insulated to prevent condensation in the vent pipe Mixing arms are not turning The mixing arms moves v...

Page 12: ...12 ...

Reviews: