Troubleshooting
Fault description
Cause
Remedy
Unit not functioning
Incorrect mains voltage
Check metering unit settings (see
Defective fuse
Replace fuse
‘Product: Reserve’
appears on display
‘Reserve’
signal active
Top up pack
(unit remains operable even
8.1 ‘Changing the application tip’
)
‘Product: Empty’
appears on display and red LED
flashes
Storage pack is emptyr
8.1 ‘Changing the application tip’
)
Disconnected or
defective cable
Reconnect
‘Empty’
signal cable or
replace it
‘Alarm: Spray air’
appears on display and red LED
flashes
Connecting cable to
solenoid valve defective
Replace connecting cable
Solenoid valve defective Replace solenoid valve
‘Alarm: Control valve’
appears on display and red LED
flashes
Connecting cable to
solenoid valve defective
Replace connecting cable
Solenoid valve defective Replace solenoid valve
When the cause of the problem has been removed, press ‘ENTER’ to
acknowledge the fault.
When the cause of the problem has been removed the applicator is ready
to work again.