10.3.12.2
Displayanzeige in der Betriebsebene bei aktiviertem Dosierregler
▼ = Downward metering divergence
The pump is currently delivering less than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is increased automatically until the actual value matches the
target value.
-
= No metering divergence
The pump delivers exactly the preset flow
(here 100/min for example).
No correction is necessary.
▲ = Upward metering divergence
The pump is currently delivering more than the preset stroke frequency
(here 100/min for example) requires.
Metering frequency is reduced automatically until the actual value matches the
target value.
HINWEIS
1 = Dongle Box mounted.
2 = Oval gear meter OGM
PLUS
mounted.
10.3.13 Configuration / Metering monitoring
If the metering monitoring function is enabled, the pump strokes are compared to the
incoming pulses using a connected external metering monitor (e.g. oval gear meter).
If a configurable tolerance threshold is breached, an alarm is triggered.
The metering monitoring system can be connected at plug II (or plug V if a dongle box is
used) at Pin 2+4 (input pulse) or at Pin 3+4 (input metering lock) (assortment of inputs
Chapter 10.3.13.5 ‘Metering monitoring / Input (only at E60 WITHOUT Dongle box)’
), electrical connection
Chapter 8.2.1.1 ‘Installing the oval gear meter
NOTICE!
If an oval gear meter is connected as a metering monitoring unit and should be
correspondingly evaluated, then the configuration/oval gear meter function
must be enabled in addition to the configuration/metering monitoring function
(
Chapter 10.3.11 ‘Configuration / Oval gear meter (only E60
).
Menu description
82
417101442 Rev. 12-02.2019
Summary of Contents for Elados EMP KKS E60
Page 2: ......
Page 123: ...14 2 Abmessungen Abb 89 Abmessungen Technische Daten 121 417101442 Rev 12 02 2019 ...
Page 135: ......
Page 258: ...14 2 Dimensions Fig 90 Dimensions Technical Specifications 122 417101442 Rev 12 02 2019 ...
Page 393: ...14 2 Dimensions Fig 93 Dimensions Données techniques 123 417101442 Rev 12 02 2019 ...
Page 405: ......