6
Startup / Operation
Starting up
Proceed as follows:
1.
Switch on the commercial dishwasher.
2.
Configure the machine.
3.
Fill the wash tank with clean water.
4.
If necessary, perform the datum calibration.
5.
Set the concentration to approx. 3.5 mS/cm (starting value).
6.
Make all other parameter settings.
For this, compare the manuals of the corresponding electronics variant.
7.
If necessary, reset the operating data memory unit.
8.
Open shut-off valve on water supply pipe.
9.
Check that all hoses, connections and components are properly sealed and check
that the capsule switch functions properly.
10.
Insert a cleaning agent capsule and start the rinse program of the commercial
dishwasher.
11.
After 2-3 program runs, check the concentration by means of titration.
If necessary, correct the required conductivity figure.
NOTICE!
Before titration, the preparation value must have reached about 100 % of
the nominal value.
Startup / Operation
22
417102610 Rev. 01-12.2020