Ecolab BFE3 Service Manual Download Page 3

1.1 General information               EN

For safety reasons it is important to read all of the 

enclosed information (Installation guide, service 

manual, spare parts, operating instructions) before 

mounting this equipment. In addition, the legislation in 

force at the time of purchase must always be consid-

ered in connection with installation and mounting of 

this equipment, no matter the contents of this manual. 

If there are matters of dispute please contact your 

dealer.

This equipment is produced and tested by specially 

qualified personnel according to approved instructions 

to ensure our high level of product quality. After the 

product is finished and tested it is manually inspected 

with the ultimate test carried out just before the prod-

uct is released for shipping. To obtain our high level 

of quality and long life we use stainless steel parts. 

These parts, in defiance of our manual inspections 

may still have some sharp edges, which can present 

a cut hazard. Therefore, it is advised always to use 

protective gloves and show caution when installing the 

equipment.

1.2 Preparation

Note:

  The pipeline must be rinsed through before 

the system is connected. See service manual

1.3 Placing/application

•  Do not use the machine outdoors. 

•  The Booster must be placed in frost-free rooms 

only.

•  Free space around the Booster: min 1000 mm.

1.4 Water supply

BFE3

Water amount

100 l/min.

Pressure

0,2 - 0,8 MPa (2 - 8 bar)

Max. temperature

70

o

C

The supply line must be sized so that it can supply the 

minimum indicated pressure and water volume when 

connected to this equipment. When dimensioning the 

water supply. It is recommended to increase the avail-

able volume with 15-20% compared to the minimum 

requirements listed in the table.

Note:

  Recommended water hardness 14-18 dH°. 

The equipment will operate with water hardness ex-

ciding this level however, descaling of pump system, 

injectors and like must be expected depending on use 

pattern and water quality. 

1.5 Electric connection 

Connection guide is mounted on the cable:

Always check direction of rotation.

Service switch:

A separate service switch must always be mounted 

before the unit.

Note!

 Installation always according to the country’s 

legislation.

BFE3

Voltage:

380 - 415V

Frequency:

50 Hz

Motor effect:

5,5 kW

Nom. Voltage:

12,2 A

Fuse:

16 A

L1, L2, L3, PE

1,5 mm²

1.6 Piping

The pipe system should be made of stainless steel 

pipes. The pipe joints should be made in a way that 

makes separation possible in case of eg.  repairs, 

moving or similar.

All threads according to ISO 228

The dimensions stated are all indicative.

Always carry out calculations of the piping installation 

based on pressure charts  for piping and fittings

Pipe connections

BFE3

Recommended pipe dimen-

sions

5/4" 

Pipe dimensions unit

5/4" 

Note:

   5/4” – 2” closing valve should be mounted on 

the water supply immediately before the Booster and 

dirt filter if any.

1.7 Assembly

Dimensions see fig.1.

Mount the Booster to the floor with the enclosed con

-

crete anchors.

3

Summary of Contents for BFE3

Page 1: ...Eco Booster BFE3 Service Manual 3 14...

Page 2: ...tenance 10 2 3 Start 10 2 3 1 New System 10 2 4 Daily Operation 10 2 4 1 Start 10 2 4 2 Stop 10 2 4 3 Rinsing the Chemistry supply 10 2 5 Service 10 2 5 1 Components 10 2 5 2 Recycling and scrapping 1...

Page 3: ...2 0 8 MPa 2 8 bar Max temperature 70o C The supply line must be sized so that it can supply the minimum indicated pressure and water volume when connected to this equipment When dimensioning the wate...

Page 4: ...0 300 1 1 4 386 210 105 Fig 1 110002069 Fig 2 110002162 Appox 1600 482 520 Appox 970 1 1 4 1 1 4 386 Fig 1 110002049 Fig 2 110002049_1 Type BFE3 Type BFE3 med tilbeh r 1 8 Dimensions Ma e Dimensions D...

Page 5: ...kt 1 6 und 3 eingehalten werden En montant les unit s satisfont veillent employer les dimensions de pipe num r es dans la table au point 6 et les illustrations au point 3 Al montar las unidades satisf...

Page 6: ......

Page 7: ...se the water from the system for applications other than cleaning Important Do not use the water from the system for other purposes than cleaning If the above instructions are not following the cleani...

Page 8: ...Eco Booster BFE3 Fig 5 1 Pump coupling inlet 2 Pump 3 Pump coupling outlet 4 Controller 5 Temperature sensor 6 Stop button 7 Start button 8 Fig 5 110002032 1 5 3 4 2 6 7 7 6 Fig 6 110002163...

Page 9: ...Operating Diagrams accorrding to ISO14617 Eco Booster BFE3 B Ball valve F Filter C Non return valve TE Temperature sensor CP Centrifugal pump D Outlet W Water inlet 9 Fig 7 110002195 C1 W TE1 B1 F1 C...

Page 10: ...Stop the pump 5 Loosen the relief plug 1 2 times again and bleed the sy stem until inly water flows out 6 Tighten the relief plug once more 2 4 Daily operation 2 4 1 Start 1 Check that water and air...

Page 11: ...ician Is there voltage to the unit Yes Reconnect voltage No OK 11 Is there sufficient water supply Yes No Clean the filter or buy a new one Is the pump leaking or making jarring sounds Increase the in...

Page 12: ...ax operational pressure Mpa bar 2 5 25 Min inlet pressure Mpa bar 0 2 2 Max inlet pressure Mpa bar 0 8 8 Min Water supply L min 100 Max water temp C 70 Inlet pipe inch 1 1 4 Outlet pipe inch 1 1 4 Ele...

Page 13: ...2 9 Electric diagram 13...

Page 14: ...2 10 Pumpcurve 14 0 5 10 15 20 25 0 20 40 60 80 100 120 140 160 180 200 Pressure bar Flow l min Pumpecurve CRN 5 32 5 5kW CRN 5 32 5 5 kW 2 bar supply...

Page 15: ...aatimustenmukaisuusvakuutus Overensstemmelseserkl ring Deklaracja zgodno ci Megfelel s gi nyilatkozat Izjava o skladnosti Izjava o uskla enosti Deklaracija o konformitetu Declara ie de Conformitate Pr...

Page 16: ...00 3 3 2008 Dichiarazione di conformit Nilfisk ALTO dichiara sotto la sua esclusiva responsabilit che i prodotti BFE Eco Booster ai quali fa riferimento la presente dichiarazione sono conformi alle di...

Page 17: ...yksinomaisella vastuulla ett tuotteet BFE Eco Booster jota t m vakuutus koskee noudattavat direktiivej jotka k sittelev t EY n j senvaltioiden lakien yhdenmukaisuutta koskien seuraavia Toiminto Pumppu...

Page 18: ...pod vlastitom odgovorno u da je proizvod BFE Eco Booster na koji se ova izjava odnosi u skladu s direktivama ovog Vije a o uskla ivanju zakona dr ava lanica EU Funkcija Pumpna postaja Model vrsta BFE3...

Page 19: ...rinin AB yesi lkelerin kanunlar n birbirine yakla t rma zerine unun yaln zca bizim sorumlulu umuz a stasyonu akine Direktifi 2006 42 EC 2006 05 17 Kullan lm standartlar EN 55014 1 A1 2009 ve EN 55014...

Page 20: ...tais standarts EN 61000 3 2 A2 2009 un EN 61000 3 3 2008 p atbilst d m Padomes d likumdo anas norm F Modelis tips BFE3 S rijas numurs visi Ma nu direkt va 2006 42 EK 17 05 2006 Izmantotais st Elektrom...

Page 21: ......

Page 22: ...2005 All rights reserved Ecolab GmbH Co OHG P O Box 13 04 06 D 40554 D sseldorf www ecolab com Tel 49 211 98 93 203 Fax 49 211 98 93 223 Printed in Denmark No 110002037B 09 2012 Printed in Denmark...

Reviews: