Use Left/Right arrow keys to set the desired time (3
–
30 seconds). Default is 3 seconds.
Press SK#3 <Save> to save selection.
Press <Back> to cancel selection and return to previous screen.
1)
The system is shipped with this feature disabled for all 3 liquid products. There is a row of 3 connectors and
OPEN plugs (S1-S3) located at the bottom of the IO board. This simulates an always-full product. If the jumper
is connected (
‘S’ and ‘
-
‘
pins are closed), an empty product alarm will be displayed and logged.
2)
The
‘
+
’
pins are reserved for the capacitive sensor (future use).
Do not connect the ‘+’ pins to stand
ard sensor.
If the installation uses only 1 float sensor (1 liquid product pail) with 3 washing machines, the wiring needs to use
jumpers so any washer can determine an Out Of Product Alarm.
2.2.7
Submenu #2.7 Quick Setup>Alarm Volume
Adjust the alarm volume using this screen.