9.2.2
Install the metering valves in the correct position
Fig. 20: Install the metering valves in the correct position
The direction of flow is marked by an impressed arrow on the suction/pressure valves.
WARNING!
When installing the valves, ensure that the flow direction is correct.
9.2.3
Changing the valve cartridges, V3 type
When changing the V3 valve cartridges, be sure to insert them in the
correct position. During installation, the small O-ring (pos. 3) must be
installed facing downwards (towards the pump head).
The lower valve cartridge is installed without O-rings.
However, the position also corresponds to that of the upper cartridge here.
Consequently, the groove, in which the large O-ring (pos. 2) would fit, must
point in the direction of the pump head.
Fig. 21: Changing the valve cartridges, V3 type
1
Valve cartridge V3
2
O-ring ø 7 x 1.5
3
O-ring ø 2.5 x 1.5
P
Pressure side -> pressure valve
S
Suction side -> suction valve
Maintenance
46
417101964 Rev. 4-04.2019
Summary of Contents for 141277
Page 2: ......
Page 137: ...67 417101964 Rev 4 04 2019...