background image

EN

1

Technical Specifications

Basic Information

Net Weight

14 kg  (31 lbs)

Dimensions (L × W × H)

48 cm × 14 cm × 30 cm  (18.9“ x 5.5” x 11.8“)

Wi-Fi

Supported

 

 (<120 Meters)

Bluetooth 

(v4.0)

Supported  (<15 Meters)

Output Spec

Pure sine wave, 3600 W (surge 7200 W, 100 ms), 

230 V, 50 Hz (Australian Version: 240 V, 50 Hz)

Linear derating to 1800 W when 40℃ (104°F) < Ambient 

Temperature < 60℃ (140°F)

Derating to 3000 W when battery voltage < 49 V

Maximum AC Output 

Supported by X-Boost

13.6 V 70 A, maximum power: 

1000 W

or 26.4 V 60 A, maximum power: 1600 W

Input Spec

3000 W maximum power, 15 A maximum current, 

supported by EcoFlow  X-Stream Technology

AC Input Voltage

220–240 V, 50 Hz/60 Hz 

PV Input 2/3

15–60 V 30 A, maximum power: 

1600 W

Alternator Input

PV Input 1

13–60 V 60 A, maximum power: 1000 W

15–60 V 30 A, maximum power: 1600 W

Battery Port Spec

40-60 V 100 A, supports up to three 2kWh or 5kWh LFP 

batteries, which are sold separately.(Not recommended to 

use one Power Hub with both a 2kWhLFP and 5kWh battery 

at the same time.)

Operating Environment

Operating Temperature

–25°C to 60°C (-13°F to 140°F)

Storage Temperature

–25°C to 60°C (-13°F to 140°F)

Other 

EcoFlow Smart Generator

1800 W maximum charging power, sold separately.

AC Output

DC

 Output

5200 W

Battery Port (x3)

AC Input Power

Summary of Contents for POWER HUB

Page 1: ...POWER HUB EFM100 HUB HV User Manual V1 0...

Page 2: ......

Page 3: ...this product it is deemed that you understand approve and accept all the terms and content in this document EcoFlow is not liable for any loss caused by the user s failure to use this product in compl...

Page 4: ...n the Box Care and Maintenance FCC Statement System Overview Product Overview CAN Bus Connection Power On Off DC Output AC Output AC Charging Smart Generator Charging Solar Charging Vehicle Alternator...

Page 5: ...c 3000 W maximum power 15 A maximum current supported by EcoFlow X Stream Technology AC Input Voltage 220 240 V 50 Hz 60 Hz PV Input 2 3 15 60 V 30 A maximum power 1600 W Alternator Input PV Input 1 1...

Page 6: ...agnetic fields 10 Do not disassemble this product in any way or pierce it with sharp objects 11 Do not use wires or other metal objects that may result in a short circuit 12 Do not use unofficial comp...

Page 7: ...safety reasons it is recommended to install a Ground Fault Circuit Interrupter GFCI also known as Residual Current Device RCD in the AC input and AC output of the Power Hub Please refer to local regul...

Page 8: ...4 4 4 2 AC DC Smart Distribution Panel 6 Shore Power Grid Power 9 Vehicle Alternator 1 EcoFlow Power Hub 3 Power Kit Console 4 EcoFlow 2kWh 5kWh LFP Battery 5 EcoFlow Smart Generator 7 Rigid Flexible...

Page 9: ...European Version Australian Version 6 Main Power Button 7 DC OUT Button 8 AC OUT Button 9 AC Out Indicator 10 DC Out Indicator 11 AC IN Indicator 12 PV IN 2 3 Indicator 13 ALT IN PV IN 1 Indicator 14...

Page 10: ...throughout the system Not doing so will cause the system to malfunction 1 When neither the AC DC Smart distribution Panel nor the Power Kit Console is connected two RJ45 CAN Bus terminators must be c...

Page 11: ...Hub before shutting down the Power Kits When the power is on short press the DC button to enable DC Output To disable DC Output short press the DC button Product Usage DC OUT White light stays on Erro...

Page 12: ...AC Charging The EcoFlow Power Hub features EcoFlow fast charging technology X Stream The maximum AC charging power is 3000 W and the maximum AC charging current is 15 A User can adjust the charging cu...

Page 13: ...Flow Smart Generator as shown below DC Charging Connect EcoFlow Smart Generator to the Power Hub with the Smart Generator Charging Cable Smart Generator and charging cable are sold separately AC Charg...

Page 14: ...orts and 1600 W for each port PV2 3 ports are dedicated PV input ports PV1 can be connected to a vehicle alternator for charging or be used as a PV input port The maximum input current is 30 A each PV...

Page 15: ...lternator charging cable from the Power Hub when vehicle is not in use for a long time X Boost Feature 1 The X Boost feature is unavailable when AC Output is in bypass mode 2 The X Boost feature is no...

Page 16: ...the product is connected to external AC and the AC output is enabled the system enters bypass mode The AC output is provided by the external AC power supply and the LFP battery is charged by the exte...

Page 17: ...ut 5 Which devices can connect to the AC output port of this product The rated power of the AC output port of this product is 3600W and surge power is 7200W It can supply power to most home appliances...

Page 18: ...14 What s in the Box Mounting Kit Back 1 M5 20 7pcs M4 10 6pcs User Manual 1 Warranty Card 1 Quick Start Guide 1 Mounting Kit Bottom 1 RJ 45 CAN Bus Terminator 2 Solar Charge Cable 6m 20ft 1 Power Hub...

Page 19: ...void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limi...

Page 20: ......

Page 21: ...POWER HUB EFM100 HUB Benutzerhandbuch V1 0...

Page 22: ......

Page 23: ...verwenden wird davon ausgegangen dass Sie alle Bedingungen und Inhalte dieses Dokuments verstehen genehmigen und akzeptieren EcoFlow haftet nicht f r Sch den die dadurch entstehen dass der Nutzer das...

Page 24: ...CAN Busabschl ssen 6 VERWENDUNG DES PRODUKTS 8 Ein Ausschalten 8 Gleichstromausgang 8 Wechselstromausgang 9 Wechselstromladung 9 Smart Generator Ladung 10 Solarladung 10 Ladung ber die Fahrzeug Licht...

Page 25: ...Wechselstrom Eingangsleistung Das X Stream Schnellladeger t unterst tzt eine maximale Leistung von 3000 W und einen maximalen Strom von 15 A Wechselstromeingangs Spannung 220 240 V 50 Hz 60 Hz PV Eing...

Page 26: ...e dieses Produkt nicht in Umgebungen mit starker statischer Elektrizit t oder Magnetfeldern 10 Bauen Szie dieses Produkt nicht auseinander und stechen Sie nicht mit scharfen Gegenst nden hinein 11 Ver...

Page 27: ...den 5 Es wird nicht empfohlen den LFP Akku anzuschlie en oder abzuklemmen wenn das System eingeschaltet ist Datenschutzrichtlinie Durch die Nutzung von EcoFlow Produkten Anwendungen und Diensten erkl...

Page 28: ...andstrom Campingplatz 7 Rigides oder flexibles Solarmodul 8 Faltbares tragbares Solarpanel 9 Fahrzeug Lichtmaschine 1 EcoFlow Power Hub 2 AC DC Smart Disribution Panel 3 Power Kit Konsole 4 EcoFlow 5...

Page 29: ...IN Anschluss 5 AC OUT Anschluss 10 A Britische Version Europ ische Version Australische Version 6 Netzschalter 7 DC OUT Schalter 8 AC OUT Schalter 9 AC Out Anzeige 10 DC Out Anzeige 11 AC IN Anzeige...

Page 30: ...m die Kommunikation im gesamten System zu stabilisieren Andernfalls kommt es zu einer Fehlfunktion des Systems 1 Wenn weder das AC DC Smart Distribution Panel noch die Power Kit Konsole angeschlossen...

Page 31: ...Ger t eingeschaltet ist dr cken Sie kurz den DC Schalter um den Gleichstromausgang zu aktivieren Um den Gleichstromausgang zu deaktivieren dr cken Sie erneut kurz den DC Schalter Verwendung des Produ...

Page 32: ...inen Stromverlust zu vermeiden Wechselstromladung Der EcoFlow Power Hub verf gt ber die EcoFlow Schnellladetechnologie X Stream Die maximale Wechselstrom Ladeleistung betr gt 3000 W und der maximale W...

Page 33: ...nten dargestellt aufgeladen werden Gleichstromladung Verbinden Sie den EcoFlow Smart Generator mit dem 5 m langen Akkuanschlusskabel Smart Generator und Anschlusskabel sind separat erh ltlich mit dem...

Page 34: ...f r jeden einzelnen Anschluss Die PV2 3 Anschl sse sind dedizierte PV Eingangsanschl sse PV1 kann zus tzlich zum PV Laden zum Laden an die Lichtmaschine des Fahrzeugs angeschlossen werden Der maximal...

Page 35: ...Funktion 1 Die X Boost Funktion ist nicht verf gbar wenn sich der Wechselstromausgang im Bypass Modus befindet 2 Die X Boost Funktion ist nicht f r alle Ger te geeignet Die X Boost Funktion ist eher f...

Page 36: ...Wechselstromquelle angeschlossen ist und der Wechselstromausgang eingeschaltet wird geht das System in den Bypass Modus ber Der AC Ausgang wird von der externen AC Versorgung gespeist und der LFP Akk...

Page 37: ...selstromausgang dieses Produkts angeschlossen werden Die Nennleistung des Wechselstromausgangs dieses Produkts betr gt 3 600 W und die berspannungbetr gt 7 200 W Es kann die meisten Haushaltsger te mi...

Page 38: ...ieferumfang Montagesatz R ckseite 1 M5 20 7 Stk M4 10 6 Stk Benutzerhandbuch 1 Garantiekarte 1 Schnellstartanleitung 1 Montagesatz Unterseite 1 RJ 45 CAN Busabschluss 2 Solar Ladekabel 6 Meter 1 POWER...

Page 39: ...genehmigt wurden k nnen die Befugnis des Benutzers das Ger t zu betreiben aufheben HINWEIS Dieses Ger t wurde getestet und entspricht den Grenzwerten f r einen digitales Ger t der Klasse A entsprechen...

Page 40: ...Ecoflow App...

Reviews: